User's Manual
6. To manually switch up and down of the shutter, simply press S1 or S2 .
7. PAN08 built in meter function and can read the Watt , KWh, V(Voltage),
I(Current) , PF(Power Factor) of the load by using Z-Wave command class, user
can set a threshold watt to get the warning caused by abnormal operation
8. PAN08 have overload protection function, and can help to prevent short circuit
caused by load.
Programming
1. Basic Command Class
The PAN08 will respond to BASIC and BINARY commands that are part of the
Z-Wave system.
1.1 BASIC_GET
When PAN08 receive Basic Set Command
,
it will send Basic Report Command
to report the position of the curtain
。
When the report value is 0x00, that mean the
Shutter is bottom down, if the report value is 0xFF or 0x63 that mean the Shutter
is at the top, any other value between0x01~0x62 imply Shutter at 1%~99%
position
;
But if report value is 0xFE means the position is unknown
。
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command
:
[Command Class Basic, Basic Report, Value = 0x00 (BOTTOM)]
[Command Class Basic, Basic Report, Value = 0x01~0x62 (Between BOT-
TOM and TOP)]
[Command Class Basic, Basic Report, Value = 0xFE (UNKNOWN)]
[Command Class Basic, Basic Report, Value = 0x63/0xFF (TOP)]
1-2 BASIC_SET
PAN08 can only accept Basic Set Command which value is either (0x00)Bottom or
Top (0x63/0xFF)
,
other value is not acceptable
[Command Class Basic, Basic Set, Value = 0x63
或
0xFF] control the
shutter to the top (0xFF)
。
[Command Class Basic, Basic Set, Value = 0x00(0)] control the shutter to
the bottom(0x00)
。
2
Binary Switch Command Class
4