User's Manual
Value = 0xFE(UNKNOWN)]
[Command Class Multilevel Switch, Multilevel Switch Report,
Value = 0x63/0xFF(TOP)]
3-3 MULTILEVEL SWITCH START LEVEL CHANGE:
This is the command which user can move the shutter to the
particular posi-
tion ex. 60% of total range
[Command Class Multilevel Switch, Multilevel Switch Start Level Change,
Up/Down Value , Inc/Dec Value, Step Size Value]
。
3-3.1 Up/Down Bit :
If Up/Down Bit=0x00 Shutter move up
;
If Up/Down Bit=0x01 Shutter move down
;
If Up/Down Bit=0x03 no move
3-3.2 Inc/Dec Bit
:
If Inc/Dec Bit=0x00 means New Step_Size = Now Step_Size + Step_Size
;
If Inc/Dec Bit=0x01 means New Step_Size = Now Step_Size - Step_Size
;
If Inc/Dec Bit=0x03 means New Step_Size = Now Step_Size
3-3.3 Step_Size
:
Range from 0x00~0x63 or 0xFF, default value=50, and the meaning of 0x63 and
0xFF is 100% of total range. If the Now Step_Size + Step_Size >100, the new
Step_Size will stay at 100 , if the Now Step_Size - Step_Size <0 , the New
Step_Size will stay at 0
Example 1
:
If user want shutter move up , and the distance is 60% of total
range(assume the now Step_Size= 50)
Command Class Multilevel Switch
Multilevel Switch Start Level Change
Up/Down = 0x00 (UP = 0x00)
Inc/Dec = 0x00 (Increment = 0x00
:
Step_Size = 50+10 = 60)
Step_Size = 10 This value represent how many the new
step_size want to increase or decrease
Example 2
:
If user want shutter move down , and the distance is 50% of total
range(assume the now Step_Size= 50)
Command Class Multilevel Switch
Multilevel Switch Start Level Change
Up/Down = 0x01 (Down = 0x01)
Inc/Dec = 0x03 (No Inc/Dec = 0x03
:
not change Step_Size
value
,
Step_Size = 50)
Step_Size = 0 This value represent how many the new
step_size want to increase or decrease,
when Inc/Dec = 0x03 please set this value to
0)
6