User's Manual
Example 3
:
If User not go to change shutter position but only change
Step_Size to 40%( assume the now Step_Size= 50)
Command Class Multilevel Switch
Multilevel Switch Start Level Change
Up/Down = 0x03 (No Up/Down motion = 0x03)
Inc/Dec = 0x01 (Decrement = 0x01
:
Step_Size = 50–10 =
40)
Step_Size = 10 This value represent how many the new
step_size want to increase or decrease
ATT.1. Ignore_Start_Level
、
Start_Level
、
Dimming_Duration can not be used
2. PAN08 can not control the speed of motor
。
3-3.4 MULTILEVEL SWITCH STOP LEVEL CHANGE:
When receive Multilevel Switch Stop Level change Command PAN08 will stop the
motor
。
4 Z-wave’s Groups introduction (Association Command Class Version 1 )
There is only one group called Group1
,
there is only one node for Group1 which
support MULTILEVEL_SWITCH_REPORT
、
METER_REPORT_COMMAND_V3
、
ALARM_REPORT
。
4-1 Report the shutter position :
Every time when user press S1 or S2 and let shutter to move, PAN08 will report the
position status to controller, and at the moving process when change over 10%
PAN08 will send Multilevel Switch Report to Group 1 also.
Multilevel Switch Report:
Ex. Report position at 30%
[Command Class Multilevel Switch, Multilevel Switch Report,Value = 30(%)]
4-2 Meter Command Class
:
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated
power consumption(KWH) or (3)
AC load Voltage (V) or (4)
AC load current ( I )
(5)
load power factor (PF) to Z-Wave Controller after receive the Meter Get
Command from Z-Wave Controller.
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Group as well
4-2.1 Instant Power Consumption (Watt) of Switch
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Report Command: [Command Class Meter
,
Meter Report
,
scale(bit
2) +Rate Type +Meter Type
,
Precision + Scale(bit 1,0)+ Size
,
Meter
Value 1
,
Meter Value 2
,
Meter Value 3
,
Meter Value 4]
Rate Type = 0x01
Meter Type = 0x01
Precision = 1
Scale = 0x02(W)
Size = 4 Bytes (Meter Value)
Meter Value 1 = (W) MSB
7