User Manual

Configuration
Parameter
Function Size
(Byte)
Value Unit Default Description
1 Watt Meter
Report Period
2 0x01-
0x7FFF
5s 720 5*720s=3600s=1 hour
2 KWH Meter
Report Period
2 0x01-
0x7FFF
10min 6 6*10min= 1 hour
3
3-1
Watt
Meter Report Period:
If the setting is configured for 1hour (set value =720), the PAN11 will report its
instant power consumption every 1 hour to Z-Wave Controller. The maximum
interval to report its instant power consumption is 45 hours
(5s*32767/3600=45hr).
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN11 will report its
Accumulated Power Consumption (KW/h) every 1 hour to Z-Wave Controller. The
maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55
days (10min*32767/1440=227.55 days).
4. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_VERSION
* COMMAND_CLASS_SWITCH_ALL
* COMMAND_CLASS_ASSOCIATION_V1
* COMMAND_CLASS_METER_V3
* COMMAND_CLASS_CONFIGURATION
Socket Type
Since the socket type for each country in Europe varies, refer to the outline for each
socket suited for each country as follows:
Germany type PAN11-1
8