User's Manual

Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the setting
still keep, don't reset to factory default. Unless the user execute the
“RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no effect.
NO. Name Def. Valid A B C Description
1
Basic Set
OFF Level
0 All
Setting the BASIC command value.
When the flood trigger off(0x00), send
the BASIC CC to the group 2.
2
Basic Set
ON Level
0xFF All
Setting the BASIC command value.
When the flood trigger on(0xFF), send
the BASIC CC to the group 2.
5
(*)
Operation
Mode
All 0 33 32 Operation mode. Using bit to control.
0 Bit0: Disable the Flood function.
0 Bit1: Reserve.
0 Bit2: Reserve.
0
Bit3: Setting the temperature scale.
0: Fahrenheit, 1:Celsius
0 Bit4: Reserve.
0
Bit5: Disable the temperature report
after event triggered. (1:Disable,
0:Enable)
0 Bit6: Reserve.
0 Bit7: Reserve.
6
(*)
Mult-
Sensor
Function
Switch
All 0 64 64
Multisensor function switch. Using bit
to control.
0 Bit0: Reserve.
0 Bit1: Reserve.
0 Bit2: Reserve.
0 Bit3: Reserve.
0 Bit4: Reserve.
0 Bit5: Reserve.
6