Installation Instructions
• Failed or success in add/remove the node ID can be viewed 
from Z-Wave
TM
 Controller.
Notice 1: Always RESET a Z-Wave
TM
 device before trying to add it to a
Z-Wave
TM
 network
Z-Wave
TM
 Notification
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the “Wake Up Notification”
message   to   the   network,   and   wake-up   10   seconds   for   receive   the
setting commands.
The  wake-up  interval minimum setting   is  30 minutes,  and  maximum
setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please press the
button once. The device will wake-up 10 seconds.
Z-Wave
TM
 Message Report
When CO Sensor detects, the device will report the trigger event and
also report the battery status.
In   default   the   device   will   using   Notification   Report   to   represent   the
trigger event, it can be changed to Sensor Binary Report by setting the
configuration NO. 7 Bit4 to 1.
* CO Detected/Test Report:
When the CO Sensor detects CO, the device will unsolicited to send 
the CO detected (0x02) report to the nodes in the group 1. When the 
device is in alarm test mode, the device will unsolicited to send the CO 
Sensor test (0x03) report to the nodes in the group 1.
Notification Report (V4)
Notification Type: CO (0x02)
Event: CO detected, Unknown Location (0x02)
 CO Alarm Test (0x03)
Sensor Binary Report (V2)
Sensor Type: CO (0x03)
Sensor Value: 0xFF
* Tamper Report:
When the tamper is pressed, the device will into the alarm state. In that
state, if tamper is released, the yellow LED will light on and the device
will unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)
Sensor Value: 0xFF
Notice : When the event triggered, the device will report the messages
to the nodes in the group 1. The messages also include the tamper
status.
Power Up Procedure
* Wake
When the device power on, the device will wake about 20 seconds. In
3