Installation Instructions
CO alarms for minimum security
Figure 1: Location for placing CO 
alarm for A multi-floor 
Do not place the CO alarm in the following areas:
(a) Where the temperature may drop below 40℉ (4.4℃) or exceed 
100℉ (37.8℃)
(b) Near paint thinner fumes
(c) Within 5 feet (1.5 meter) of open flame appliances such as 
furnaces, stoves and fireplaces
(d) In exhaust streams from gas engines, vents, flues or chimneys
(e) Do not place in close proximity to an automobile exhaust pipe; this 
will damage the Alarm
Z-Wave Supported Command Class
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1.
*  The   configuration   mark   with   star   (*),   means   after  the   remove   the
setting still keep, don't reset to factory default. Unless the user executes
the “RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no effect
NO. Name Def. Valid Description
7
(*)
Custome
r 
Function
4 All
Customer function switch, using bit 
control.
0 Bit0: Reserve.
0 Bit1: Reserve.
1 Bit2: Reserve.
0 Bit3: Reserve.
0 Bit4: Notification Type, 
8