Installation Instructions

0: Using Notification Report.
1: Using Sensor Binary
Report.
0 Bit5: Reserve.
0 Bit6: Reserve.
0 Bit7: Reserve.
10
Auto
Report
Battery
Time
12 0~127
The interval time for auto report the
battery level.
0 means turn off auto report
battery. Each tick means 30
minutes. The default value is 12(6
hours).
Specifications
Operating Voltage DC4.5V (3 x AA 1.5V alkaline battery)
Battery life Up to one year
Operating Temperature 0°C ~ 50°C (85% humidity)
Storage Temperature -20 C ~ 60°C
FCC ID RHHPSG04
RF Range (distance) Minimum 40M in door and 100M in
outdoor, line of sight
Frequency Range 868.40MHz; 869.85MHz (EU)
908.40MHz; 916.00MHz (US)
916.00 MHz (IL), (Israel), (PSG04-IL)
922~927MHz (Japan)
920~924MHz (Taiwan; Korea)
865.20 MHz (IN),
869.00 MHz (RU),
921.40 MHz, 919.80 MHz (ANZ),
RF Maximum Power
(peak)
+5dBm (peak) For EU RED directive
RF Maximum Power
(Average)
-10dBm (Average) For EU RED
directive
RF Modulation Type FSK (Frequency-Shift Keying)
Sensitivity: Comply to UL2034 and EN50291
This CO sensor PSG04 meets following mentioned response
times:
UL2034
At 70ppm, the unit must alarm within 60-240 minutes
At 150ppm, the unit must alarm within 10-50 minutes
At 400ppm, the unit must alarm within 4-15 minutes
EN50291:
At 50ppm , the unit must alarm within 60-90 minutes
At 100ppm, the unit must alarm within 10-40 minutes
At 300ppm, the unit must alarm within 3 minutes
9