User Manual
Slim Multi-Sensor PSM02  
The slim multi-sensor PSM02 has PIR, door/window, temperature and
illumination, 4 sensors function in one, based on Z-Wave
TM
 technology.
Z-Wave
TM
  is   a   wireless   communication   protocol   designed   for   home
automation, specifically to remotely control applications in residential
and light commercial environments. The technology uses a low-power
RF radio embedded or  retrofitted into  home  electronics  devices and
systems, such as lighting, home access control, entertainment systems
and household appliances.
This device is one component of the Z-Wave
TM
  sensor system and is
designed to work with all other Z-Wave
TM
  enabled devices in a home
control network. The device adopt the Z-Wave
TM
 400 series chip, when
your   Z-Wave
TM
  network   system   is   all   made   by  Z-Wave
TM
  400   series
devices. The network system will have the advantages as below.
• Concurrent multi-channel support reduces external interference.
• Better RF range, improve about 10 meters in indoor.
• Support 100 Kbps transmit speed, speed up communication.
Adding to Z-Wave
TM
 Network
There  are  two  tamper  keys  in  the  device,  one   is  in  the   back  side,
another is in the front side. They have the same function. Both of them
can inclusion, exclusion, reset or association from Z-Wave
TM
 network.
In the first time, add the device into the Z-Wave
TM
 network. First, make
sure the primary controller is in the inclusion mode. And then power on
the device, just take out the insulation Mylar in the back side of the 
device. The device will auto start the NWI (Network Wide Inclusion) 
mode. And it should be included in 5 seconds. You will see the LED 
light ON one second.
Function
Description
Inclusion
1. Have Z-Wave
TM
 Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds
will enter inclusion mode.
3. After inclusion successful, the device will wake to 
receive the setting command from Z-Wave
TM
Controller about 20 seconds.
Exclusion
1. Have Z-Wave
TM
 Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds
will enter exclusion mode.
Node ID has been excluded.
Reset
1. Pressing tamper key four times within 1.5 seconds 
and do not release the tamper key in the 4
th
pressed, and the LED will turn ON.
2. After 3 seconds the LED will turn OFF, after that 
within 2 seconds, release the tamper key. If 
successful, the LED will light ON one second. 
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to 
factory default.
1