User's Manual

3
Timer
1. Entering the timer mode:
A. Pointing the arrowhead to area A.
B. Pressing and hold the button about three to five seconds. The red
LED will light then go out. Release the button when the light goes out
and the buzzer will sound long beep once.
2. Exit the timer mode:
A. Pointing the arrowhead to area A.
B. Pressing and hold the button about three to five seconds. The red
LED will light then go out. Release the button when the light goes out
and the buzzer will sound beep twice.
3. Setting up timer: Pointing the arrowhead to the zone you want to count
down (shown in Fig. 3). The countdown will begin after you pressing the
button and sound beep.
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is -10°C~40°C.
3. Do not locate the Switch where exists combustible substances or any
source of heat, e.g. fires, radiators, boiler etc.
Z-Wave’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to control associated Z-Wave devices. It
supports 2 association groups which every group has eight node support.
For group 1, the Switch will report event to Z-Wave Controller. Eg. Battery state
For group 2, the Switch can control ON/OFF status of lamps
1.
Firmware update over the air (OTA)
PSR04 is based on 500 series SoC and supports Firmware Update Command
Class, it can receives the updated firmware image sent by controller via the
Z-wave RF media. It is a helpful and convenient way to improve some function if
needed.
2.
Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO_V2
* COMMAND_CLASS_BATTERY
* COMMAND_CLASS_CENTRAL_SCENE_V1
* COMMAND_CLASS_VERSION_V2
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_WAKE_UP_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_MULTI_CMD
* COMMAND_CLASS_SECURITY
* COMMAND_CLASS_MARK
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
* COMMAND_CLASS_CONFIGURATION