User's Manual
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can detected long
distance, but if there is more noise signal
in the environment, it will re-trigger too 
frequency. 
4
Light 
Threshold
99 0~100
Setting the illumination threshold to turn 
on the light. When the event triggered 
and the environment illumination lower 
then the threshold, the device will turn 
on the light.
0 means turn off illumination detected 
function. And never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination detected
function. And always turn on the light.
Notice: In none test mode, only the 
value in 1 to 99 will enable the 
illumination detected function and 
update the illumination value.
5 Operation 
Mode
0 0~127 Operation mode. Using bit to control.
Bit0: 1 means security mode, 
 0 means home automation mode.
Bit1: 1 means enable test mode, 
 0 means disable test mode.
Notice: 
Bit0 and bit1 will effect when the DIP 
Switch setting to program mode.
If bit1 is enabled, the bit0 is useless.
Bit2: Disable the door/window function.
Bit3: Setting the temperature scale.
 0: Fahrenheit, 1:Celsius
Bit4: Disable illumination report after 
event triggered.
Bit5: Disable temperature report after 
event triggered.
6
Multi-Sensor 
Function 
Switch
4 0~127
Multi-Sensor function switch. Using bit to
control.
Bit0: Disable magnetic integrate 
illumination.
Bit1: Disable PIR integrate Illumination.
Bit2: Disable magnetic integrate PIR 
(Default is Disable)
Bit3: When Bit2 is 0 (Enable), the device 
is install in the same room with the light?
 0: In the same room(Default),
 1: In the different room.
Bit4: Disable delay 5 seconds to turn off 
the light, when door/window closed.
Bit5: Disable auto turn off the light, after
door/window opened to turn on the 
light. 
Notice: If bit2 is zero, this setting is 
useless.
Bit6:Enable temperature monitoring.
When this bit enable, the temperature 
changed 3 degree Fahrenheit, it will 
report.
And also the temperature over 140 
degree Fahrenheit, it will report every 64
seconds.
8