User Instructions
N
O.
Name
Def
.
Valid Description
0 Bit7:  Reserve.
12
PIR Re-
Detect 
Interval Time
6 1 ~ 60
In the normal mode, after the PIR 
motion detected, setting the re-
detect time. 10 seconds per tick, 
default tick is 6 (60 seconds).
Setting the suitable value to 
prevent received the trigger signal 
too frequently. Also can save the 
battery energy.
Notice: If this value bigger than the 
configuration setting NO. 13. There
is a period after the light turned off 
and the PIR not start detecting.
13
Turn Off Light
Time
6 1 ~ 60
After turn on the lighting, setting 
the delay time to turn off the 
lighting when the PIR motion is not 
detected. 10 seconds per tick, 
default tick is 6 (60 seconds).
0 means never send turn off light 
command.
14
Auto Report 
Battery Time
12 0 ~ 127
The interval time for auto report the
battery level.
0 means turn off auto report 
battery.
The default value is 12. The tick 
time can setting by the 
configuration No.17.
15 Auto Report 
LightSensor 
Time
12 0 ~ 127 The interval time for auto report the
illumination.
0 means turn off auto report 
N
O.
Name
Def
.
Valid Description
illumination.
The default value is 12. The tick 
time can setting by the 
configuration No.17.
16
Auto Report 
Temperature 
Time
12 0 ~ 127
The interval time for auto report the
temperature.
0 means turn off auto report 
temperature.
The default value is 12. The tick 
time can setting by the 
configuration No.17.
17
Auto Report 
Tick Interval
30
0 ~
0xFF
The interval time for auto report 
each tick. Setting this configuration 
will effect configuration No.14, 
No.15 and No.16.
The unit is 1 minute.
Caution1: Setting to 0 means turn 
off all auto report function.
Caution2: The value is unsigned 
byte, the range is from 0x00 ~ 
0xFF.
18 Temperature 
Differential 
Report
1 0 ~ 127 The temperature differential to 
report.
0 means turn off this function. 
The unit is Fahrenheit.
Enable this function the device will 
detect every minutes.
And when the temperature is over 
140 degree Fahrenheit, it will 
continue report.
Enable this functionality will cause 
8