User Instructions
N
O.
Name
Def
.
Valid Description
some issue please see the detail in
the “Temperature Report” section.
19
LightSensor 
Differential 
Report
10 1~100%
The LightSensor Differential to 
report.
0 means turn off this function.
The unit is percentage.
Enable this function the device will 
detect every percentage.
And when the lightSensor is over 
10 percentage, it will continue 
report.
20
Temperature 
Threshold 
line 1
20
- 20 ~
50C
Temperature difference return:
The default is 20 degrees C.
21
Temperature 
Threshold 
line 2
25
- 20 ~
50C
Temperature difference return:
The default is 25 degrees C.
22
Temperature 
Threshold 
line 3
30
- 20 ~
50C
Temperature difference return:
The default is 30 degrees C.
23
Temperature 
Threshold 
line 4
35
- 20 ~
50C
Temperature difference return:
The default is 35 degrees C.
24
Temperature 
Threshold 
line 5
40
- 20 ~
50C
Temperature difference return:
The default is 40 degrees C.
25 PIR Trigger 
Mode
1 1~3 PIR Trigger Mode:
Mode1: Normal
Mode2: DayTime
N
O.
Name
Def
.
Valid Description
Mode3: AtNight
26
PIR 
NightLine
1 1~100
PIR night line Lux conditions:
LightSensor determines whether 
the level is night. (Unit 100Lux)
Z-Wave Supported Command Class
Command Class Version Required Security Class
Z-Wave Plus Info
2 None
Version
3 Highest granted Security Class
Manufacturer Specific
2 Highest granted Security Class
Security 2
1 None
Device Reset Locally
1 Highest granted Security Class
Association
2 Highest granted Security Class
Association   Group
Information
1 Highest granted Security Class
Powerlevel
1 Highest granted Security Class
Basic
1 Highest granted Security Class
Configuration
1 Highest granted Security Class
Notification
8 Highest granted Security Class
Firmware   Update   Meta
Data
4 Highest granted Security Class
Supervision
1 None
9