3.4.1 Electrical and lighting characteristics of ‘TL’5 HE lamps
Note: 1) Data after 100 operating hours.
Measuring conditions:
Position:free burning,horizontal position
Operating frequency = 25 kHz
In a reference circuitry according to IEC standardization
In the following tables the electrical and photometrical data are given:
Reference ballast Nominal conditions at T
amb.
= 25 °C
Lamp Colour Rated Calibration Resistance Discharge Lamp Lamp Luminous
type voltage current current voltage power flux
VmA mA V W cd/m
2
TL5 HE 14W /827,/830,/835, /840 167 170 500 165 86 ± 10 13,7 1200
/850,/865 1100
TL5 HE 21W /827,/830,/835, /840 246 170 725 165 129 ± 10 20,7 1900
/850,/865 1750
TL5 HE 28W /827,/830,/835, /840 329 170 950 170 170 ± 17 27,8 2600
/850,/865 2400
TL5 HE 35W /827,/830,/835, /840 413 170 1200 170 215 ± 20 34,7 3300
/865 3100
Conditions at top of lumen curve at T
amb.
= approx.35 °C
Lamp Colour Discharge Lamp Lamp Luminous Luminous Luminance
type current voltage power flux efficacy
mA V W lm lm/W cd/m
2
TL5 HE 14W /827,/830,/835, /840 170 82 ± 10 13,7 1350 96 1,7 x 10
4
/850,/865 1250 89 1,5 x 10
4
TL5 HE 21W /827,/830,/835, /840 170 123 ± 10 20,7 2100 100 1,7 x 10
4
/865 1950 93 1,6 x 10
4
TL5 HE 28W /827,/830,/835, /840 170 167 ± 17 27,8 2900 104 1,7 x 10
4
/850,/865 2700 96 1,6 x 10
4
TL5 HE 35W /827,/830,/835, /840 170 209 ± 20 34,7 3650 104 1,7 x 10
4
/865 3400 97 1,6 x 10