Indoor Furnishings User Manual

2000-11-07
11
Lamp Discharge Lamp Lamp Luminous Luminous
type current voltage power flux efficacy
mA V W lm lm/W
TL5 HE 14W 130 89 11 1140 104
170 82 13,7 1350 96
220 78 17 1590 94
TL5 HE 21W 130 132 17 1770 104
170 123 20,7 2100 100
220 116 25 2470 99
TL5 HE 28W 130 178 23 2440 106
170 167 27,8 2900 104
220 156 34 3410 100
TL5 HE 35W 130 220 28 3070 110
170 209 34,7 3650 104
220 192 42 4290 102
In the following table the dependency on the discharge current is given at top of the lumen curve.
Luminous flux and efficacy in the table below are only applicable for colours /827,/830, /835 and /840. For colours /850 and /865 the ratio
is in line with the preceding table.
Note: 1) Data after 100 operating hours.
2) A discharge current less than the lowest value given for each lamp type will have a negative effect on lamp life unless extra electrode
heating is used to keep the electrode at a sufficiently high temperature.
3) A discharge current of more than the highest value given for each lamp type will have a negative effect on lamp life.
4) The bold printed values correspond with the nominal lighting characteristics
5) Data at 35 ºC ambient temperature.