Energy controlled preheating
Depending on the available time for preheating, the ballasts should
give a preheating energy within the following limits:
E = Q + P x t
2000-11-07
17
Lamp Preheating Preheating time Substitution
type energy Q P resistor
J 0,5 s 1,0 s 1,5 s 2,0 s 3,0 s J W (R
sub
)
TL5 HE min. 1,35 1,75 2,15 2,55 3,35 0,95 0,8 31,0
max. 2,70 3,50 4,30 5,10 6,70 0,95 0,8 31,0
TL5 HO
24W min. 1,95 2,50 3,05 3,60 4,7 1,40 1,1 8,2
max. 3,90 5,00 6,10 7,20 9,4 1,40 1,1 8,2
39W min. 1,95 2,50 3,05 3,60 4,7 1,40 1,1 8,2
max. 3,90 5,00 6,10 7,20 9,4 1,40 1,1 8,2
54W min. 3,40 4,10 4,80 5,50 6,9 2,70 1,4 5,1
max. 6,80 8,20 9,60 11,00 13,8 2,70 1,4 5,1
49W min. 1,70 2,10 2,50 2,90 3,7 1,30 0,8 13,0
max. 3,40 4,20 5,00 5,80 7,4 1,30 0,8 13,0
80W min. 3,25 3,80 4,35 4,90 6,0 2,70 1,1 4,5
max. 6,50 7,60 8,70 9,80 12,0 2,70 1,1 4,5
4.1.3 Lamp ignition
Ignition with preheating.
The following table includes values for the open-circuit voltages,
which an electronic ballast should generate for two different
ranges of ambient temperatures (indoors and outdoors).
Note: The open-circuit voltages are valid for:
- sinusoidal voltages (crest factor 1,4),frequency 20 - 26 kHz,
- applications with an earthed plate at a distance of 6 mm,
- properly preheated coils.
Ignition without preheating:cold ignition
The published lifetime of a lamp is based on a switching cycle of
165 minutes on and 15 minutes off with preheated coils,which is
considered as representative for general lighting applications.
However, the TL5 lamps can be ignited without preheating.This
will lead to more damage to the coil during the ignition phase.For
this reason,we do not recommend cold ignition with frequent
switching.However,cold ignition can be an option for not
frequently switched lamps,like lamps burning for at least 8 hours
per switch.More information on the dependency of lifetime on
preheating conditions and switching cycle can be found in the
separate brochure Life expectancy, lumen maintenance and service
life curves of Fluorescent lamps (TL and CFL-NI) 3222 635 18911.
Lamp Voltage During Ignition at Ignition at Substitution
type preheating 10 to 60 °C -15 to 60 °C resistor
V(R
sub
)
TL5 HE
14W min.(r.m.s.) 230 275 40,0
max.(r.m.s.) 130 40,0
21W min.(r.m.s.) 340 390 40,0
max.(r.m.s.) 200 40,0
28W min.(r.m.s.) 425 530 40,0
max.(r.m.s.) 240 40,0
35W min.(r.m.s.) 530 700 40,0
max.(r.m.s.) 275 40,0
TL5 HO
24W min.(r.m.s.) 280 350 12,0
max.(r.m.s.) 130 12,0
39W min.(r.m.s.) 350 390 12,0
max.(r.m.s.) 175 12,0
54W min.(r.m.s.) 520 620 8,0
max.(r.m.s.) 240 8,0
49W min.(r.m.s.) 450 625 16,5
max.(r.m.s.) 225 16,5
80W min.(r.m.s.) 580 750 7,0
max.(r.m.s.) 250 7,0