Specifications

Design-in guide Philips Fortimo LED Line High Voltage System 25
Lumen depreciation as a function of operating hours for LED Line 1ft 1100lm 3R HV1 at
different Tc values
Note that the above graphs are lifetime predictions based on LM80 data; no
guarantee outside specified lifetime specifications.
Operating windows *
Data for LED Line 1 ft 650lm 3R HV1
3000 K
3500 K
4000 K
5000 K
Current
mA
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
75
310
135
330
142
335
145
345
148
125
495
125
520
131
530
134
540
137
175
660
118
695
124
710
127
725
129
225
830
112
870
118
890
121
910
123
Data for LED Line 1 ft 1100lm 3R HV1
3000 K
3500 K
4000 K
5000 K
Current
mA
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
150
650
141
670
144
680
147
690
149
200
845
135
865
138
880
141
895
143
250
1030
130
1055
133
1075
136
1095
138
300
1215
126
1240
129
1265
131
1290
134
350
1395
122
1430
125
1455
128
1480
130
400
1570
119
1605
122
1635
124
1665
126
Data for LED Line 2 ft 2200lm 1R HV1
3000 K
3500 K
4000 K
5000 K
Current
mA
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
flux
lm
efficiency
lm/W
150
1230
131
1260
134
1285
136
1310
139
200
1590
124
1630
127
1660
130
1690
132
250
1940
119
1990
122
2025
124
2060
126
300
2280
114
2335
117
2380
119
2425
122
350
2620
110
2680
113
2730
115
2780
117
400
2945
107
3015
109
3070
111
3125
113
Tc nom 35 °C
Tc life 62 °C
Tc max 70 °C
Ref: 18W T8
Specification
Min.B50L70
0%
100%0%
100%
0 10,000 20,000 30,000 40,000 50,000 60,000
Lumen depreciation (%)
Lumen maintenance (%)
Lumen maintenance (B50)
Fortimo LED Line 1ft 1100lm 3R HV1
Operating lifetime (hours)
70%
50,000 hours proven by certified
laboratory