HID Lamps and Gear
3.
HID Lamps HID Lamps HID Lamps Today, outdoor lighting is expected to do much more than simply enable us to see at night. Lighting has also become an essential tool that is widely used to create a more welcoming environment. Outdoor lighting, therefore now has both functional and decorative roles to play. In addition, the wide choice of lamps available means that there are many outdoor lighting solutions for each application area.
3.
HID Lamps HID Lamps Urban architectural lighting of buildings, bridges, statues and gardens can also help to create a nightscape even more striking than the same area as seen by day. Today’s architectural lighting does not necessarily involve high light levels but models architectural features with color and shade. High light quality and even colored right sources are appropriate in this application.
MASTER MHN-SA Product Description ● Compact quartz metal halide lamps with double-pinch Product Features ● Very compact source (Short Arc) with high luminous efficacy and superior colour rendering ● Double-pinch concept results in long lifetime ● Natural white colour appearance, high colour rendering and good colour stability ● Daylight colour temperature eases transition from daylight to artificial lighting Product Benefits ● Allows compact and very efficient luminaire systems with high precisi
MASTER MHN-SA Type ANom CMax DMax ONom XNom 318 369 41 25 25 C HID Lamps MASTER MHN-SA XW UNP A D O X MHN-SA XW MHN-SA (P)SFC Technical data Type Lamp Lamp Lamp Current Wattage Voltage Voltage Rated EM EM (A) (W) (V) (V) MASTER MHN-SA 1800W/856/956 230V XW/(P)SFC UNP 17.3 1800.0 120 230 1800 MASTER MHN-SA 1800W/956 (P)SFC 400V UNP 10.5 1850.0 205 400 1800 MASTER MHN-SA 2000W/956 400V XW UNP 11.3 2040.
MASTER MHN-SA Spectral power distribution 10 W/nm W/nm 10 8 8 6 6 4 4 2 2 400 500 700 600 [nm] MHN-SA 1800W 230V 400 500 700 600 [nm] MHN-SA 1800W /956 400V W/nm 20 16 12 8 4 400 500 700 600 [nm] MHN-SA 2000W /956 400V Performance diagram Lamp performance during run up % 200 160 Ila 120 80 40 Wla Vla 0 1 2 3 4 5 t MHN-SA 100 Lumen in % Lumen in % Lumen maintenance diagram 90 80 90 80 70 70 60 60 50 0 1000 2000 MHN-SA 1800W /856/956 230V/400V 3.
MASTER MHN-SA 90 80 100 90 80 70 70 60 60 50 0 1000 3000 2000 4000 5000 Burning hours MHN-SA 1800W /856/956 230V/400V Cap Base HID Lamps 100 Survivals in % Survivals in % Life expectancy diagram 50 0 1000 2000 3000 4000 5000 Burning hours MHN-SA 2000W /956 400V Operating position 18 (P)SFC p15 OEM Catalogue 2009/2010 3.
MASTER MHN-LA Product Description ● Compact quartz metal halide lamps with double-pinch Product Features ● Compact source (Long Arc) with high luminous efficacy ● Double-pinch concept results in long lifetime ● Natural white colour appearance, high colour rendering and good colour stability ● Daylight colour temperature eases transition from daylight to artificial lighting Product Benefits ● Allows compact and efficient luminaire systems with precision optics for good beam control and minimal sp
HID Lamps MASTER MHN-LA MHN-LA 1000W Technical data Type Lamp Lamp Lamp Current Wattage Voltage Voltage Rated EM EM (A) (W) (V) (V) MASTER MHN-LA 1000W/842 230V XWH UNP 9.3 1040.0 125 230 1000 MASTER MHN-LA 2000W/842 400V XWH UNP 9.6 2040.0 235 400 2000 MASTER MHN-LA 2000W/956 400V XWH UNP 10.3 2040.
MASTER MHN-LA 20 W/nm W/nm 25 20 16 15 12 10 8 5 4 400 500 [nm] 700 600 MHN-LA 2000W /842 400V 400 500 600 700 [nm] MHN-LA 2000W /956 400V Performance diagram Operating position Lamp performance during run up % 200 160 120 Ila 80 Wla 40 0 Vla 2 4 6 8 10 t MHN-LA p5 100 Lumen in % Lumen in % Lumen maintenance diagram 90 80 100 90 80 70 70 60 60 50 0 2000 4000 6000 8000 50 10000 Burning hours MHN-LA 1000W /842/956 230V 0 3000 6000 9000 12000 Burning h
HID Lamps MASTER MHN-LA OEM Catalogue 2009/2010 3.
MHN-SB Product Description ● Compact quartz metal halide lamp with single pinch Product Features ● Compact source (Short Base lamp dimensions) with short electrode distance and high luminous efficacy ● Single pinch concept with long lifetime ● Natural white colour appearance, good colour rendering and stability ● Daylight colour temperature eases transition from daylight to artificial lighting Product Benefits ● Allows compact and efficient luminaire systems with precision optics for good beam c
MHN-SB Technical data MHN-SB 2000W/956 400V K12s-7 WH UNP Lamp Lamp Lamp Current Wattage Voltage EM EM Voltage (A) (W) (V) (V) 11.
HPI-T Product Description ● Quartz metal halide lamps with clear outer bulb Product Features ● Clear tubular outer bulb ● Unique 3-band technology resulting in high luminous efficacy, both initially and over long lifetime ● Renders a natural white colour appearance and good colour stability Product Benefits ● High safety and comfort level, maintained over life ● Minimal maintenance cost Application ● Sports lighting, floodlighting of buildings and monuments, area lighting e.g.
Type CMax DMax LNom ONom HPI-T 2000W/642 E40 380V CRP 430 101.5 267 120 HPI-T 2000W/646 E40 220V CRP 430 101.5 290 89 L C O D HPI-T 2000W HPI-T 1000W Technical data Type Lamp Lamp Lamp Current Wattage Voltage Voltage Rated Ignition Ignition Lamp EM EM (A) (W) (V) (V) HPI-T 1000W/643 E40 220V CRP 8.25 985.0 130 220 1000 HPI-T 2000W/642 E40 380V CRP 9.1 1955 232 380 2000 HPI-T 2000W/646 E40 220V CRP 16.5 1960.
HPI-T CRV diagram Performance diagram Lamp performance during run up b* % 200 160 I la 120 a* HPI-T 1000W 80 W la 40 V la 0 1 2 3 4 5 t HPI-T HPI-T 1000W/2000W 100 Lumen in % Lumen in % Lumen maintenance diagram 90 80 100 90 80 70 70 60 60 50 2000 0 4000 6000 8000 50 10000 Burning hours HPI-T 1000W/2000W /643/646 0 2000 4000 6000 8000 10000 Burning hours 2000 4000 6000 8000 10000 Burning hours HPI-T 2000W /642 100 Survivals in % Survivals in % Life expe
HID Lamps HPI-T OEM Catalogue 2009/2010 3.
MASTER HPI-T Plus Product Description ● Quartz metal halide lamps with clear outer bulb Product Features ● Clear tubular outer bulb ● Unique 3-band technology resulting in high luminous efficacy, both initially and over long lifetime ● Renders a natural white colour appearance and good colour stability Product Benefits ● High safety and comfort level, maintained over life ● Minimal maintenance cost ● Initial investment saving options with “Plus”-concept Application ● Sports lighting.
MASTER HPI-T Plus Technical data Lamp Lamp Lamp Rated Ignition Ignition Current Wattage Voltage Lamp Dimmable Peak Supply Life to 50% EM EM Wattage Voltage Voltage failures (A) (W) (V) (V) (V) (hrs) MASTER HPI-T Plus 250W/645 E40 SLV 2.10 245 128 250 No 5000 198 20000 MASTER HPI-T Plus 400W/645 E40 SLV 3.
MASTER HPI-T Plus Performance diagram Lamp performance during run up % 200 160 I la 120 80 W la 40 V la 0 1 2 3 4 5 t HPI-T Life expectancy diagram 100 Survivals in % Lumen in % Lumen maintenance diagram 90 80 90 80 70 70 60 60 50 4000 0 8000 12000 16000 20000 Burning hours HPI-T 250W/400W /643/645 HPI-T Cap Base Operating position 40 E40 p20 OEM Catalogue 2009/2010 50 0 4000 HPI-T 250W/400W /643/645 Photometric diagram 3.
HID Lamps MASTER HPI-T Plus OEM Catalogue 2009/2010 3.
MASTER HPI Plus Product Description ● Quartz metal halide lamps with opalized outer bulb Product Features ● Ovoid, internally white coated outer bulb ● Unique 3-band technology resulting in high luminous efficacy, both initially and over long lifetime ● Available in cool white and daylight colour appearance demonstrating good colour stability ● “S”-type for direct retrofit for HPL lamps ● “P”-type for use without protective front shield Product Benefits ● High safety and comfort level, maintai
Type C D CMax DMax MASTER HPI Plus 250W/745/767 BU E40 CRP 284 121.5 MASTER HPI Plus 250W/745 BU-P E40 SLV 218 90 MASTER HPI Plus 400W/745/767 BU E40 CRP 286 121.5 MASTER HPI Plus 400W/745 BU-P E40 CRP 226 91 MASTER HPI Plus 400W/745 BU-P E40 SLV 290 117.
MASTER HPI Plus Spectral power distribution [mW / (m2 . 5nm .
HID Lamps MASTER HPI Plus OEM Catalogue 2009/2010 3.
MASTER CityWhite CDO-TT Product Description ● Ceramic metal halide Outdoor with clear tubular outer bulb Product Features ● Robust lamp with long lifetime ● Directly retrofit on HPS (SON) installations for upgrade from yellow to white light ● Good colour rendering and harmonized warm white colour temperature Product Benefits ● Reduced cost of ownership compared to predecessor MASTERColour CDM-TT ● Comfortable warm colour impression with stable colour over lifetime ● Flexible light levels and r
Type CMax DMax LNom ONom MASTER CityWhite CDO-TT 70W/828 E27 SLV 156 32.5 102 7 MASTER CityWhite CDO-TT 100W/828 E40 SLV 209 47 132 7 MASTER CityWhite CDO-TT 150W/828 E40 SLV 211 47 132 9 MASTER CityWhite CDO-TT 250W/828 E40 SLV 255 47 157 21.
MASTER CityWhite CDO-TT Spectral power distribution Performance diagram Lamp performance during run up [W / (5nm .
HID Lamps MASTER CityWhite CDO-TT OEM Catalogue 2009/2010 3.
Artcolour MH-T Product Description ● Quartz metal halide lamps rendering coloured light Product Features ● Single-ended lamp with clear tubular outer bulb ● Available in three colours: blue, green and violet ● Suitable for direct replacement from regular white HPI-T illumination to coloured flood lighting Product Benefits ● Brings colourful light on any floodlit object and instant change of atmosphere ● High luminous output in comparison with white metal halide lamps using an additional colour f
Artcolour MH-T Technical data Lamp Lamp Rated Ignition Wattage Voltage Lamp Supply 50% Wattage Voltage failures (V) (hrs) 400 198 5000 EM (W) (V) 380 120 Artcolour MH-T 400W Blue/Green/Violet E40 SLV Life to HID Lamps Type Light data Type Luminous Colour Chromaticity Chromaticity Operating Flux Lamp Designation Coordinate X Coordinate Y Position EM (lm) Artcolour MH-T 400W Blue E40 SLV 10000 Blue 2100 1800 p20 Artcolour MH-T 400W Green E40 SLV 29000 Green 2500 5
Artcolour MH-T 100 Lumen in % Lumen in % Lumen maintenance diagram 90 80 100 90 80 70 70 60 60 50 1000 0 3000 2000 4000 50 5000 Burning hours MH-T 400W BL 0 2000 3000 4000 5000 Burning hours 1000 2000 3000 4000 5000 Burning hours 1000 2000 3000 4000 5000 Burning hours 1000 MH-T 400W GR 100 Survivals in % Lumen in % Life expectancy diagram 90 80 100 90 80 70 70 60 60 50 1000 0 3000 2000 4000 50 5000 Burning hours 0 100 100 Survivals in % MH-T 400W BL
HID Lamps Artcolour MH-T OEM Catalogue 2009/2010 3.
MASTER MHN-FC Product Description ● Compact quartz metal halide lamps with double pinch Product Features ● Double-pinch concept results in long lifetime ● Choice of 1000 W and 2000 W types ● Natural white colour appearance ● Compact light source allows small luminaire design Product Benefits ● Allows compact luminaire systems with precision optics for minimal light spill ● Good colour rendering creates a pleasant ambience with high visual comfort for players and spectators ● Continuous spect
HID Lamps MASTER MHN-FC MHN-FC 2000W Technical data Type Lamp Lamp Lamp Current Wattage Voltage Voltage Rated EM EM (A) (W) (V) (V) MASTER MHN-FC 1000W/740 230V XW UNP 10 1035 125 230 1000 MASTER MHN-FC 2000W/740 400V XW UNP 10.
MASTER MHN-FC Lumen in % Lumen in % Lumen maintenance diagram 100 90 80 70 100 90 80 70 60 60 50 50 2000 0 6000 4000 8000 10000 Burning hours MHN-FC 1000W /740/750 0 2000 4000 6000 8000 10000 Burning hours 4000 6000 8000 10000 Burning hours MHN-FC 2000W /740 100 Survivals in % Survivals in % Life expectancy diagram 90 80 60 60 2000 0 6000 4000 8000 10000 Burning hours Operating position Lamp performance during run up % 200 160 120 Ila 80 Wla 40 2 4 6 50 0 2000
HID Lamps MASTER MHN-FC OEM Catalogue 2009/2010 3.
MASTER CosmoWhite CPO-TW Product Desription ● New-generation ceramic metal halide lamps for outdoor lighting with white light, using a new lamp base and clear quartz outer bulb Product Features ● Extreme high energy efficiency ● Unique new burner design and positioning in combination with best lamp fixation (PGZ12) ● Compact size: 50% smaller than SON/HPL systems ● New electronic gear platform meets the most demanding public lighting requirements Product Benefits ● Attractive white light ● Bes
Type CMax DNom DMax LNom ONom MASTER CosmoWhite CPO-TW 45W/628 PGZ12 1CT 132 19 20 59 15 MASTER CosmoWhite CPO-TW 60W 728 PGZ12 1CT 132 19 20 59 15 MASTER CosmoWhite CPO-TW 90W/728 PGZ12 1CT 143 19 20 66 18 MASTER CosmoWhite CPO-TW 140W/728 PGZ12 1CT 147 19 20 66 20 Dimmable L C D CPO-TW PGZ12 Technical data Type Lamp Lamp Lamp Rated Ignition Ignition Ignition Run-up Current Wattage Voltage Lamp Peak Supply Time time EL EL Wattage Voltage Voltage (A)
MASTER CosmoWhite CPO-TW Spectral power distribution ��� �������������������� ������������������ ��� ��� ��� ��� ��� ��� ��� ��� ��� �� �� ��� ��� ��� ��� ��� ����� CPO-TW 45W /628 ��� ��� ��� ��� ��� ����� ��� ��� ��� ��� ����� CPO-TW 60W 300 ��� 250 �������������������� [ W / (5nm .
HID Lamps MASTER CosmoWhite CPO-TW OEM Catalogue 2009/2010 3.
MASTER CityWhite CDO-ET Product Description ● Ceramic metal halide Outdoor with opalized ovoid outer bulb Product Features ● Robust lamp with long lifetime ● Directly retrofit on HPS (SON) installations for upgrade from yellow to white light ● Good colour rendering and harmonized warm white colour temperature Product Benefits ● Reduced cost of ownership compared to predecessor MASTERColour CDM-ET ● Comfortable warm colour impression with stable colour over lifetime ● Flexible light levels and
MASTER CityWhite CDO-ET Technical data Lamp Lamp Lamp Rated Ignition Ignition Ignition Run-up Current Wattage Voltage Lamp Dimmable Peak Supply Time time Life to 50% EM EM Wattage Voltage Voltage 90% failures (A) (W) (V) (V) (V) (sec) (min) (hrs) 0.980 71 87 70 Yes 2500 198 30 3 14000 MASTER CityWhite CDO-ET 100W 1.2 95 90 100 Yes 5000 198 30 2 14000 MASTER CityWhite CDO-ET 150W 1.
MASTERColour CDM-TT Product Description ● High-intensity discharge lamps with a CDM discharge tube inside a SON lamp clear tubular outer bulb Product Features ● Robust lamp giving a pleasant white light and a stable colour over lifetime ● Good colour rendering ● Dimming not recommended because of negative effects on lamp performance (lumen maintenance, colour and life) Product Benefits ● Runs on SON gear so directly replaces equivalent wattage SON lamp for simple upgrade from yellow to white light
MASTERColour CDM-TT Technical data Lamp Lamp Lamp Rated Ignition Ignition Ignition Run-up Current Wattage Voltage Lamp Dimmable Peak Supply Time time Life to 50% EM EM Wattage Voltage Voltage 90% failures (A) (W) (V) (V) (V) (sec) (min) (hrs) MASTERColour CDM-TT 70W/942 E27 SLV 0.
MASTERColour CDM-TT Performance diagram Lamp performance during run up Lamp performance during run up Lamp performance during run up % 200 % 200 % 200 Ila 120 120 80 80 Wla 40 V la 0 160 160 160 I la W la 1 2 3 4 40 Vla 0 120 5 t CDM-TT /830 W la 80 40 I la 120 240 360 480 0 600 t (sec.) CDM-TT 70W /942 Vla 120 240 360 480 600 t (sec.
HID Lamps MASTERColour CDM-TT OEM Catalogue 2009/2010 3.
MASTER Agro Product Description ● High Pressure Sodium lamp with clear outer bulb, high lumen maintenance and increased blue radiation Product Features ● Clear tubular outer bulb ● “Agro” concept with increased blue radiation results in more compact and sturdy plant development ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a long and reliable lifetime ● ZrAl getter ensures high lumen maintenance and few early failures Product Benefits ● Optimised performance for horticultura
MASTER Agro Technical data Lamp Lamp Lamp Current Wattage Voltage EM EM MASTER Agro Voltage (A) (W) (V) (V) 4.13 423.
MASTER GreenPower Product Description ● High Pressure Sodium lamp with clear outer bulb, high lumen maintenance and optimised micromol output Product Features ● Clear tubular outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a long and reliable lifetime ● ZrAl getter ensures high lumen maintenance and few early failures ● “Green Power” concept with optimised micromol output (growth light) ● “Plus” concept with high efficacy translated into high light output Product B
MASTER GreenPower Type Lamp Lamp Lamp Current Wattage Voltage EM EM (A) (W) (V) (V) 4.230 420 113 230 400 MASTER GreenPower CG T 600W E40 6.3 605 115 230 MASTER GreenPower 600W 400V E40 3.620 608 191 400 MASTER GreenPower 600W 480V E40 3.
MASTER GreenPower 100 Lumen in % Lumen in % Lumen maintenance diagram 90 80 100 90 80 70 70 60 60 50 8000 0 16000 24000 50 32000 Burning hours SON-T 100W/150W/250W/400W 0 8000 16000 24000 32000 Burning hours 8000 16000 24000 32000 Burning hours SON-T 600W 100 Survivals in % Survivals in % Life expectancy diagram 90 80 90 80 70 70 60 60 50 8000 0 16000 24000 32000 Burning hours SON-T 100W/150W/250W/400W Cap Base Operating position E40 any OEM Catalogue 2009/2
HID Lamps MASTER GreenPower OEM Catalogue 2009/2010 3.
MASTER SON-T PIA Plus Product Description ● High Pressure Sodium lamp with clear tubular outer bulb, high output and long reliable lifetime Product Features ● Clear tubular outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a long and reliable lifetime ● Robust construction with few welding points is highly vibration- and shock-resistant, further reducing early failures and extending lamp life ● ZrAl getter ensures high lumen maintenance and few early failures ● “Plus”
MASTER SON-T PIA Plus Technical data Lamp Lamp Lamp Current Wattage Voltage EM EM Voltage Rated Dimmable Ignition Ignition Lamp Peak Supply Wattage Voltage Voltage (A) (W) (V) (V) (V) (V) MASTER SON-T PIA Plus 50W/220 E27 SLV 0.75 50.0 91 230 50 Yes 1800 198 MASTER SON-T PIA Plus 70W/220 E27 SLV 1 70.0 90 230 70 Yes 1800 198 MASTER SON-T PIA Plus 100W/220 E40 SLV 1.2 100.0 100 230 100 Yes 2800 198 MASTER SON-T PIA Plus 150W/220 E40 SLV 1.8 150.
MASTER SON-T PIA Plus Spectral power distribution 300 [�W / 5nm / lumen] [�W / 5nm / lumen] 300 250 200 150 100 250 200 150 100 50 50 400 300 500 700 600 SON-T Plus 50W/70W E27 500 600 700 �[nm] 600 700 �[nm] SON-T Plus 100W/150W/250W E40 300 [�W / 5nm / lumen] 300 [�W / 5nm / lumen] 400 300 �[nm] 250 200 150 100 250 200 150 100 50 50 400 300 500 700 600 400 300 �[nm] SON-T Plus 400W E40 500 SON-T Plus 600W E39/E40 Performance diagram Lamp performance during run up Lam
MASTER SON-T PIA Plus 90 80 90 80 70 70 60 60 50 8000 0 24000 16000 50 32000 Burning hours SON-T 600W 100 90 80 8000 16000 24000 32000 Burning hours 8000 16000 24000 32000 Burning hours 100 90 80 70 70 60 60 50 0 SON-T 50W/70W Survivals in % Survivals in % 100 HID Lamps 100 Survivals in % Lumen in % Life expectancy diagram 8000 0 16000 24000 50 32000 Burning hours SON-T 100W/150W/250W/400W 0 SON-T 600W Photometric diagram 210° 180° 150° 240° 270° 100 50
MASTER SON PIA Plus Product Description ● High Pressure Sodium lamp with opalized ovoid outer bulb, high output and long reliable lifetime Product Features ● Ovoid, internally white coated outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a long and reliable lifetime ● Robust construction with few welding points is highly vibration- and shock-resistant, further reducing early failures and extending lamp life ● ZrAl getter ensures high lumen maintenance and few early fai
MASTER SON PIA Plus Technical data Lamp Lamp Lamp Rated Ignition Ignition Ignition Run-up Current Wattage Voltage Lamp Dimmable Peak Supply Time time 50% EM EM Wattage Voltage Voltage 90% failures (V) (V) (sec) (min) Life to (A) (W) (V) MASTER SON PIA Plus 70W/220 I E27 0.980 71.50 92 70 Yes MASTER SON PIA Plus 100W/220 E40 1.2 100.0 100 100 Yes 2800 198 5 4 32000 MASTER SON PIA Plus 150W/220 E40 1.
MASTER SON PIA Plus 100 Lumen in % Lumen in % Lumen maintenance diagram 90 80 100 90 80 70 70 60 60 50 0 8000 16000 24000 50 32000 Burning hours SON PIA 50W/70W 0 8000 16000 24000 32000 Burning hours 16000 24000 32000 Burning hours SON PIA 100W/150W/250W/400W 100 Survivals in % Survivals in % Life expectancy diagram 90 80 90 80 70 70 60 60 50 0 8000 SON PIA 50W/70W Operating position any 3.
HID Lamps MASTER SON PIA Plus OEM Catalogue 2009/2010 3.
MASTER SON-T PIA Hg-Free Product Description ● High Pressure Sodium lamp with clear tubular outer bulb, long reliable lifetime and no Mercury Product Features ● Clear tubular outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a long and reliable lifetime ● Robust construction with few welding points is highly vibration- and shock-resistant, further reducing early failures and extending lamp life ● ZrAl getter ensures high lumen maintenance and few early failures ● Comp
MASTER SON-T PIA Hg-Free Technical data Lamp Lamp Lamp Current Wattage Voltage EM EM Voltage Rated Dimmable Ignition Ignition Lamp Peak Supply Wattage Voltage Voltage (A) (W) (V) (V) (V) (V) MASTER SON-T PIA Hg-Free 100W/221 E40 SLV 1.24 100.0 98 230 100 No 2800 198 MASTER SON-T PIA Hg-Free 150W/221 E40 SLV 1.8 150.0 98 230 150 No 2800 198 MASTER SON-T PIA Hg-Free 250W/221 E40 SLV 3 250 100 230 250 No 2800 198 MASTER SON-T PIA Hg-Free 400W/221 E40 SLV 4.
MASTER SON-T PIA Hg-Free Performance diagram Lamp performance during run up Lamp performance during run up % 140 % 140 I la 120 120 100 W la I la 100 W la 80 80 60 60 40 40 Vla 20 0 5 10 20 0 15 t SON-T Hg Free 100W/150W/250W Vla 5 10 15 20 t SON-T Hg Free 400W E40 Life expectancy diagram 100 Survivals in % Lumen in % Lumen maintenance diagram 90 80 90 80 70 70 60 60 50 8000 0 24000 16000 32000 Burning hours SON-T 100W/150W/250W/400W 210° 180° 150° 240° 270°
HID Lamps MASTER SON-T PIA Hg-Free OEM Catalogue 2009/2010 3.
MASTER SON PIA (Hg-Free) Product Description ● High Pressure Sodium lamp with opalized ovoid outer bulb, long reliable lifetime and no Mercury Product Features ● Ovoid, internally white coated outer bulb ● Ceramic discharge tube with Philips Integrated Antenna (PIA) for a long and reliable lifetime ● Robust construction with few welding points is highly vibration- and shock-resistant, further reducing early failures and extending lamp life ● ZrAl getter ensures high lumen maintenance and few early
MASTER SON PIA (Hg-Free) Technical data Lamp Lamp Lamp Rated Ignition Ignition Ignition Run-up Current Wattage Voltage Lamp Peak Supply Time time 50% EM EM Wattage Voltage Voltage 90% failures (A) (W) (V) MASTER SON PIA 50W/220 E27 SLV 0.76 50.0 90 MASTER SON PIA 70W/220 E27 SLV Dimmable Life to (V) (V) (sec) (min) (hrs) 50 No 1800 198 5 4 28000 0.98 70.0 90 70 No 1800 198 5 4 28000 MASTER SON PIA Hg Free 150W/221 E40 SLV 1.8 150.
MASTER SON PIA (Hg-Free) 100 Lumen in % Lumen in % Lumen maintenance diagram 90 80 100 90 80 70 70 60 60 50 8000 0 24000 16000 50 32000 Burning hours SON PIA 50W/70W 0 8000 16000 24000 32000 Burning hours 16000 24000 32000 Burning hours SON PIA 100W/150W/250W/400W 100 Survivals in % Survivals in % Life expectancy diagram 90 80 100 90 80 70 70 60 60 50 8000 0 24000 16000 50 32000 Burning hours SON PIA 50W/70W 0 8000 SON PIA 100W/150W/250W/400W Photometric diag
HID Lamps MASTER SON PIA (Hg-Free) OEM Catalogue 2009/2010 3.
SON-T Applications ● For use in road and residential lighting ● Decorative floodlighting ● Commercial and industrial applications ● Recreational sports facilities Outdoor and Indoor Why choose? ● Energy efficiency ● SON-T Pro is a cost-efficient and reliable solution in High Pressure Sodium, offering good value for money Technical Features ● High Pressure Sodium lamp with clear outer bulb ● Clear tubular outer bulb ● Robust construction is vibration- and shock-resistant leading to a reliab
HID Lamps SON-T Preferred selection Product ID Ignitor Cap/ Base Kind Packing Colour Colour Luminous Operating Order Configuration Rendering Temperature Flux Lamp Position Code EM Index (Ra) (K) (lm) SON-T 70W E E27 12 25 2000 6000 ANY 210 42515 SON-T 100W E E40 12 25 2000 9000 ANY 9284 815 00091 SON-T 150W E E40 12 25 2000 15000 ANY 210 46315 SON-T 250W E E40 12 25 2000 28000 ANY 210 52415 SON-T 400W E E40 12 25 2000 45000 ANY 210 56215 SON
SON Applications ● For use in road and residential lighting ● Decorative floodlighting ● Commercial and industrial applications Why choose? ● Energy efficiency ● SON Pro is a cost-efficient and reliable solution in High Pressure Sodium, offering good value for money Technical Features ● Ovoid, internally white coated outer bulb ● Robust construction is vibration- and shock-resistant leading to a reliable life ● Dimming possible with dedicated gear ● Require a ballast and ignitor, except fo
HID Lamps SON Preferred selection Product ID Ignitor Cap/ Base Kind Packing Colour Colour Luminous Operating Order Configuration Rendering Temperature Flux Lamp Position Code Index EM (Ra) (K) (lm) E E27 24 25 2000 5600 ANY 210 24130 SON 70W I E27 24 25 2000 5600 ANY 9284 806 00092 SON 150W E E40 12 25 2000 14500 ANY 210 28915 SON 250W E E40 12 25 2000 27000 ANY 210 38815 SON 400W E E40 12 25 2000 48000 ANY 210 32615 Dimmable SON 70W Produ
SON-T Comfort Product Description ● High Pressure Sodium lamp with clear tubular outer bulb and a comfortable colour impression Product Features ● Clear tubular outer bulb ● Warm white colour temperature and acceptable colour rendering to create a pleasant ambience ● Robust construction is vibration- and shock-resistant leading to a reliable life Product Benefits ● The ideal balance between colour impression and energy efficacy Application ● City centres and residential areas ● Decorative floo
SON-T Comfort Technical data Lamp Lamp Lamp Rated Ignition Ignition Ignition Run-up Current Wattage Voltage Lamp Dimmable Peak Supply Time time Life to 50% EM EM Wattage Voltage Voltage 90% failures (A) (W) (V) (V) (V) (sec) (min) (hrs) SON-T Comfort 150W 1.82 150.0 105 150 No 2800 198 5 6 20000 SON-T Comfort 250W 3.05 250.0 105 250 No 2800 198 5 15 20000 SON-T Comfort 400W 4.5 400.
SON Comfort Product Description ● High Pressure Sodium lamp with opalized, ovoid outer bulb and a comfortable colour impression Product Features ● Ovoid, internally white coated outer bulb ● Warm white colour temperature and acceptable colour rendering to create a pleasant ambience ● Robust construction is vibration- and shock-resistant leading to a reliable life Product Benefits ● The ideal balance between colour impression and energy efficacy Application ● City centres and residential areas ●
SON Comfort Technical data Lamp Lamp Lamp Rated Ignition Ignition Ignition Run-up Current Wattage Voltage Lamp Dimmable Peak Supply Time time Life to 50% EM EM Wattage Voltage Voltage 90% failures (A) (W) (V) (V) (V) (sec) (min) (hrs) SON Comfort 150W/621 E40 SLV 1.82 150.0 105 150 No 2800 198 5 6 20000 SON Comfort 250W/621 E40 SLV 3 250.0 105 250 No 2800 198 5 15 20000 SON Comfort 400W/621 E40 SLV 4.45 400.
SON H Product Description ● High Pressure Sodium lamp with opalized outer bulb retrofit for High Pressure Mercury lamps Product Features ● Direct replacement for mercury lamps as they operate on the same control gear ● High luminous efficacy ● Robust construction is vibration- and shock-resistant leading to a reliable life Product Benefits ● Instant and cost-effective upgrade of light level and reduction of energy use replacing HPL Application ● Road and residential lighting ● Commercial and i
SON H Technical data Lamp Lamp Lamp Rated Ignition Ignition Run-up Current Wattage Voltage Lamp Dimmable Supply Time time Life to 50% EM EM Wattage Voltage 90% failures (V) (sec) (min) (hrs) 198 10 5 28000 (A) (W) (V) SON H 68W/220 E27 SLV 0.815 69 107 68 SON H 110W/220 E27 SLV 1.29 113 109 110 No 198 15 5 20000 SON H 220W/220 E40 SLV 2.2 220.0 120 220 No 190 10 5 20000 SON H 350W/220 E40 SLV 3.6 350.
SON H 100 Lumen in % Lumen in % Lumen maintenance diagram 90 80 100 90 80 70 70 60 60 50 50 0 4000 8000 12000 16000 20000 24000 28000 32000 Burning hours SON H 110W 0 4000 6000 8000 12000 16000 24000 Burning hours 6000 8000 12000 16000 24000 Burning hours SON H 220W/350W Survivals in % Survivals in % Life expectancy diagram 100 90 80 100 90 80 70 70 60 60 50 50 0 4000 8000 12000 16000 20000 24000 28000 32000 Burning hours 0 4000 SON H 110W SON H 220W/350W
HID Lamps SON H OEM Catalogue 2009/2010 3.
MASTER SOX-E Product Description ● Low Pressure Sodium lamp with improved efficacy Product Features ● Uniform sodium distribution in the discharge tube by means of dimples for a more stable discharge, higher efficacy and better lumen maintenance and lamp life ● Special coating of SOX-E outer tube results in higher lamp efficacy than SOX ● Monochromatic yellow colour with non-existent colour rendering Product Benefits ● Extremely high luminous efficacy makes these the most efficient light sources
MASTER SOX-E Technical data Lamp Lamp Lamp Rated Current Wattage Voltage Lamp Dimmable Life to 50% EM EM Wattage failures (A) (W) (V) MASTER SOX-E 18W BY22d 1SL 0.35 18.0 57 18 No 18000 (hrs) MASTER SOX-E 26W BY22d SLV 0.45 27 69 26 No 18000 MASTER SOX-E 36W BY22d SLV 0.35 36.0 120 36 No 18000 MASTER SOX-E 66W BY22d SLV 0.62 65.0 123 66 No 18000 MASTER SOX-E 91W BY22d SLV 0.62 90.0 173 91 No 18000 MASTER SOX-E 131W BY22d SLV 0.
MASTER SOX-E Performance diagram Lamp performance during run up % 200 160 Vla 120 W la 80 I la 40 0 8 4 12 16 20 t il Life expectancy diagram 100 Survivals in % Lumen in % Lumen maintenance diagram 90 80 90 80 70 70 60 60 50 6000 0 18000 12000 50 24000 Burning hours SOX E SOX E Photometric diagram 210° 180° 150° 240° 270° 100 50 300° 330° 0° 210° 120° 240° 90° 270° 100 60° 300° 30° 180° 150° 120° 50 90° 60° 330° 0° 30° SOX E Cap Base Operating posit
HID Lamps MASTER SOX-E OEM Catalogue 2009/2010 3.
SOX Product Description ● Low Pressure Sodium lamp Product Features ● Uniform sodium distribution in the discharge tube by means of dimples for a more stable discharge, higher efficacy and better lumen maintenance and lamp life ● Monochromatic yellow colour with non-existent colour rendering Product Benefits ● High luminous efficacy leads to low energy consumption Application ● Road lighting, railway marshalling yards and crossings, airports, harbours and docks, quarries, foundries and rolling mil
SOX Technical data Lamp Lamp Lamp Rated Wattage Voltage Current Lamp 50% Wattage failures EM Dimmable Life to (W) (V) (A) SOX 35W BY22d 1SL 37 70 0.6 35 No 18000 (hrs) SOX 55W BY22d 1SL 56.0 109 0.59 55 No 18000 SOX 90W BY22d 1SL 91.0 112 0.94 90 No 18000 SOX 135W BY22d 1SL 135.0 164 0.95 135 No 18000 SOX 180W BY22d 1SL 180.0 240 0.
SOX Life expectancy diagram 100 Survivals in % Lumen in % Lumen maintenance diagram 90 80 90 80 70 70 60 60 50 0 6000 12000 18000 50 24000 Burning hours SOX SOX Cap Base Operating position 22 BY22d 3.
HID Lamps SOX OEM Catalogue 2009/2010 3.
HPL Comfort Product Description ● High pressure mercury lamp with improved colour properties and light output Product Features ● Equipped with one or two auxiliary electrodes to ensure quick and reliable ignition ● Special internal coating, providing warm white light with increased colour rendering ● Higher efficacy than standard HPL Product Benefits ● Creates a comfortable atmosphere at limited investment ● High safety level thanks high light output Application ● Public roads and residential
HPL Comfort Technical data Lamp Lamp Lamp Rated Current Wattage Voltage Lamp Dimmable Ignition Supply Life to 50% EM EM Wattage Voltage failures (A) (W) (V) (V) (hrs) HPL Comfort 50W/534 E27 SG SLV 0.61 50.0 95 50 No 180 16000 HPL Comfort 80W/534 E27 SG SLV 0.8 80.0 115 80 No 180 16000 HPL Comfort 125W/534 E27 SG SLV 1.15 125.0 125 125 No 180 16000 HPL Comfort 250W E40 HG CRP 2.13 250.0 135 250 No 180 16000 HPL Comfort 400W E40 HG CRP 3.25 400.
HPL Comfort Performance diagram Lamp performance during run up % 200 160 I la 120 80 40 Wla 0 Vla 2 4 6 8 10 t HPL Life expectancy diagram 100 Survivals in % Lumen in % Lumen maintenance diagram 90 80 100 90 80 70 70 60 60 50 4000 0 12000 8000 16000 50 20000 Burning hours HPL 50W/80W/125W/250W/400W 0 4000 HPL 50W/80W/125W/250W/400W Photometric diagram 210° 180° 150° 240° 270° 100 50 300° 330° 0° 210° 120° 240° 90° 270° 100 60° 300° 30° 180° 150° 120° 50
HID Lamps HPL Comfort OEM Catalogue 2009/2010 3.
HPL-N Standard Applications ● All outdoor applications, factories, transport sector and industrial area lighting Why choose? ● Low initial costs (higher lifetime costs) Product Features ● Standard High Pressure Mercury lamp ● Equipped with 1 electrode to ensure quick and reliable ignition ● Single-ended gas-filled glass bulb (HG-SG) with a quartz mercury vapour discharge tube ● Internally coated ovoid outer bulb, providing a cool, bluish white light with reasonable colour qualities Recommended
HID Lamps HPL-N Standard Preferred selection Product ID Cap/ Base Packing Colour Colour Luminous Operating Order Configuration Rendering Temperature Flux Lamp Position Code Index EM (Ra) (K) (lm) HPL-N 50W/542 E27 24 49 4200 1800 ANY 9280 505 07396 HPL-N 80W/542 E27 24 48 4200 3700 ANY 9280 510 07396 HPL-N 125W/542 E27 24 46 4100 6200 ANY 9280 520 07396 HPL-N 250W/542 E40 12 45 4100 12700 ANY 9280 530 07496 HPL-N 400W/542 E40 6 45 3900 22000 ANY 92
ML High Pressure Mercury Applications ● Public outdoor lighting, car parks, workshops, garages and shops Why choose? ● Direct retrofit for incandescent lamps ● Higher efficacy and lifetime than incandescent Technical Features ● High-pressure mercury tube in series with a tungsten filament ● Runs on mains voltage without additional gear ● Combines a continuous spectrum from the incandescent source and a line spectrum from the high-pressure mercury source ● It is recommended to protect ML agains
Burning position Universal Burning position HID Lamps ML High Pressure Mercury Burning position ML 100 W ML 160 W ML 250 W ML 500 W Preferred selection Product ID lamp Packaging Soft Glass/ Colour Colour Luminous Base Configuration Hard glass Rendering Temperature flux lamp EM Index (Ra) (K) (lm) Order Code ML100W E27 24 SG 72 3300 1100 9280 900 57296 ML160W B22 24 SG 65 3600 3150 9286 010 11401 ML160W E27 24 SG 65 3600 3150 9286 010 08988 ML250W E27 12 SG
HID Control Gear HID Gear HID Control Gear The Philips HID electronic gear range was designed for total compatibility with Philips HID lamps. Philips is leader in the field of electronic technology and we have applied this knowledge to our developments of control gear for lighting products. Each lamp and gear combination requires extensive life testing before being released as a complete system. The result is an optimal light performance.
MASTERColour 3.
HID Control Gear HID Gear Besides electronics a broad selection of electromagnetic gear is offered for wide range of lamp types and powers from 35W up to 2000W. You can rely on the experience of Philips and the fact that all Philips lamps are fully released that performance of Philips lamps are best on Philips gear. Electromagnetic HID gear Depending on the specific application and/or economic considerations, Philips can supply two types of electromagnetic ballasts; Heavy Duty and Basic gear types.
HID-PrimaVision SON and CDO Product Description ● Compact, one-piece, electronic drivers for high-pressure sodium (SON) lamps and metal halide (CDO) lamps Features and Benefits ● Lamp power independent of lamp life and mains voltage 203-254V ● Low-frequency, electronic gear for stable, flicker-free lamp operation; increases lamp life by 20 – 30% depending on application ● Self-stopping facility prevents cycling of old lamps ● Full protection of driver and installation against fault conditions such
HID-PrimaVision SON and CDO Type A2 A1Nom A2Nom A3Nom B1Nom B2Nom C1Nom D1Nom 150.0 134.0 136.0 90.0 70.0 40.0 4.5 HID Gear D1 B1 B2 HID-PrimaVision SON/CDO C1 A3 A1 HID-PV Inrush current Type Maximum Inrush Inrush gear number current current on MCB Peak Width (x) (A) (ms) HID-P 70 /S SON/CDO 220-240V 50/60Hz 8 35 0.5 HID-P 100/150 /S SON/CDO 220-240V 50/60Hz 8 50 0.
HID-PrimaVision SON and CDO Electrical installation notes Inrush current Mains operation Conversion table for max. quantities of drivers on other types of Rated mains voltage 220 - 240 V Miniature Circuit Breaker With tolerances for performance 203 - 254 V MCB type Rating +6%-8 Relative number of drivers With tolerances for operation 180 - 264 V Mains frequency 50/60 Hz B 16 A Power factor > 0.98 B 10 A 63% Earth leakage current < 0.
HID Gear HID-PrimaVision SON and CDO OEM Catalogue 2009/2010 3.
HID-DynaVision SON and CDO Product Description ● Compact, one-piece, electronic dimming driver for built-in or standalone applications with high-pressure sodium (SON) and metal halide lamps (CDO) Features and Benefits ● 1-10V input for dim-control signal ● Lamp power independent of lamp life and mains voltage 203-254V ● Low-frequency, electronic, dimmable gear for stable, flicker-free lamp operation; increases lamp life by 20 – 30% depending on application ● SON lamps can be dimmed between 100 - 3
HID-DynaVision SON and CDO Type A2 A1Nom A2Nom A3Nom B1Nom B2Nom C1Nom D1Nom 150.0 134.0 136.0 90.0 70.0 40.0 4.5 HID Gear D1 B1 B2 HID-DynaVision 1-10V SON/CDO C1 A3 A1 HID-DV Inrush current Type Maximum Inrush Inrush gear number current current on MCB Peak Width (x) (A) (ms) 8 50 0.5 12 35 0.
HID-DynaVision SON and CDO Notes: Inrush current 1. With three-phase mains supply, neutral should never be Conversion table for max. quantities of drivers on other types of disconnected; otherwise circuitry could be damaged. Miniature Circuit Breaker 2. For proper EMC, wiring inside luminaire should be as straight and as MCB type Rating short as possible; mains wires should not run parallel to lamp wires. 3. Driver should be mounted in luminaire > min IP 23.
HID Gear HID-DynaVision SON and CDO OEM Catalogue 2009/2010 3.
HID-DynaVision DALI SON and CDO Product Description ● Compact, one-piece, electronic dimming driver for built-in or standalone applications with high-pressure sodium (SON) and metal halide lamps (CDO) ● Digital DALI interface to communicate with and program the driver Features and Benefits ● DALI interface enables two way communication ● Lamp power independent of lamp life and mains-voltage 203-254V ● Low-frequency, electronic, dimmable gear for stable, flicker-free lamp operation; increases lamp
HID-DynaVision DALI SON and CDO Type A2 A1Nom A2Nom A3Nom B1Nom B2Nom C1Nom D1Nom 150.0 134.0 136.0 90.0 70.0 40.0 4.5 HID Gear D1 B1 B2 HID-DynaVision DALI C1 A3 A1 HID-DV Inrush current Type Maximum Inrush Inrush gear number current current on MCB Peak Width (x) (A) (ms) 6 50 0.
HID-DynaVision DALI SON and CDO Notes: 1. Data is based on a mains supply with an impedance of 400 mΩ Control characteristics Control input DALI Input is protected against mains voltage connection (equal to 15 m cable of 2.5 mm2and other 20 m to the middle of the Dimming fading rates are implemented to guarantee optimal lamp power distribution), under worst case conditions. With an impedance of 800 mΩ the number of drivers can be increased by 10%.
HID Gear HID-DynaVision DALI SON and CDO OEM Catalogue 2009/2010 3.
HID-EXC for SOX lamps Product Description ● One-piece, compact, lightweight high-frequency electronic driver Features and Benefits ● Replaces electromagnetic gear, ignitor and capacitor ● Provides equivalent light output at up to 36% lower energy consumption ● One multi-voltage unit gives constant light output at mains voltages between approximately 200 and 255 V ● Slim cross-section and light weight facilitate luminaire design ● Single-insert contacts ● Simple installation and cabling Applic
Type A1Nom A2Nom B1Nom C1Nom D1Nom EXC 35/36/55/66 SOX(-E) 280.0 265.0 39.0 28.0 4.2 EXC 91 SOX-E 335.0 325.0 39.0 28.0 4.2 C1 B1 D1 A2 A1 EXC Inrush current Type Inrush Inrush current current Peak Width (A) (ms) EXC 35/36 SOX(-E) 30 0.15 EXC 55/66 SOX(-E) 40 0.15 EXC 91 SOX-E 50 0.
HID-PrimaVision CPO-TW Xtreme Product Description ● Compact, robust, outdoor, one-piece, electronic gears for CosmoPolis White (CPO-TW) lamps Features and Benefits ● Single easily-installed, self-contained component ● High system efficiency – up to 92% ● Xtreme long lifetime gear: 60,000 hours 95% survival rate (or 80,000 hours with 90% survival rate) at nominal temperature ● Peak voltage protection safeguards the lamp; surge protection safeguards the gear (differential mode/common mode 2kV/4kV)
Type A2Nom B1Nom B2Nom C1Nom D1Nom 135.0 125.7 65.0 46.8 65.0 4.8 HID-PrimaVision Xtreme 90/140 /S CPO-TW 150.0 140.7 65.0 46.8 65.0 4.8 D1 A1Nom HID-PrimaVision Xtreme 45/60 /S CPO-TW C1 B1 B2 A2 A1 HID-PV Xt Inrush current Type Maximum Inrush Inrush gear number current current on MCB Peak Width (x) (A) (ms) HID-PrimaVision Xtreme 45/60 /S CPO-TW 220-240V 50/60Hz 11 37 0.29 HID-PrimaVision Xtreme 90/140 /S CPO-TW 220-240V 50/60Hz 5 56 0.
HID DynaVision LumiStep Product Description ● Stand-alone dimming, lightweight, one-piece electronic gear for CosmoWhite lamps Features and Benefits ● Step dimming from 100% down to 60% within three preprogrammed cycles - 6, 8 and 10 hours – at start times determined in the dimming cycle ● No external control components nor additional signal wiring required ● Single easily-installed, self-contained component ● High system efficiency – up to 92% ● Xtreme long lifetime gear: 60,000 hours 95% survi
HID DynaVision LumiStep Type A2 A1Nom A2Nom B1Nom B2Nom C1Nom D1Nom 135.0 120.9 65.0 46.8 65.0 4.8 HID Gear D1 C1 B1 B2 HID-DLS Xt 60 CPO-TW A1 HID-DV Inrush current Type HID-DLS Xt 60 CPO-TW Maximum Inrush Inrush gear number current current on MCB Peak Width (x) (A) (ms) 11 37 0.
HID-DynaVision Control SON Product Description ● HID-DynaVision Controller for combination with dimming gear (BSH), electromagnetic gear (BSN) and ignitor Features and Benefits ● Offers the possibility of creating 250W and 400W SON dimming systems with electromagnetic gear ● Can be added on to existing luminaires, practically no cable-length restrictions ● Light level can be continuously dimmed from 100 to 20% (approx.
HID-DynaVision Control SON CE-marking Approval marking ISO 14001 KEMA/VDE CE-marking HID-electronics Environmental standard Safety EN 61347-2-1/2-3/2-9 Performance EN 60927 / EN 60929 RFI EN 55015 / EN 55022 Harmonics EN 61000-3-2 EMC immunity EN 61547 ISO 14001 HID Gear Environmental standard Recommended lamp page 3.170 www.philips.com/OEM BSH Inrush current Type Inrush Inrush current current Peak Width (A) (ms) 3.6 0.
HID-DynaVision Control SON Electrical installation notes Control characteristics Mains operation Control input Rated mains voltage 220 - 240 V Control voltage input 1-10 V With tolerances for performance 203 - 254 V Protected against mains voltage Yes With tolerances for operation 180 - 264 V connection Mains frequency 50/60 Hz Control resistance (to be Operation frequency (typical) 50 Hz connected on 1-10V input) Power factor* (nominal power) > 0.
HID Gear HID-DynaVision Control SON OEM Catalogue 2009/2010 3.
HID-SDU for regulating systems Product Description ● Interface for two-level control of electronic gears with 1-10V dim input with 230V switched line signal Features and Benefits In combination with ● HF-Regulator for Fluorescent lamps: dimming from 100 to 50% ● In combination with HID-DynaVision drivers for SON (SDU-01/H) or CDO (SDU-01/L) lamps: dimming from 100 to 50% ● When SDU is connected the dim-input of the electronic gear is not galvanically isolated anymore! ● SDU in synthetic ’standard’
HID-SDU for regulating systems Electrical data Number Rated Line Line T-case of Gear- Frequency Voltage maximum SDU-01/H /L Lamps Lamp (x) Power (Hz) (V) (ºC) 1-4 13-600 50/60 220-240 85 T-ambient HID Gear Type 80 Ordering and packing data Type Weight Qty bulk Dimensions bulk packing packing EAN code EOC bulk packing 8727900 SDU-01/H 0.043 kg 20 20 cm x 17.5 cm x 11 cm 8711500747297 800845 00 SDU-01/L 0.043 kg 20 20 cm x 17.
HID-Basic BSN/BMH semi-parallel ignitor Product Description ● Impregnated electromagnetic copper/iron gears for use with an external semi parallel ignitor for CDM, CDO, MH, HPI (Plus) and SON lamps Features and Benefits ● Compact dimensions and light weight with minimal watt losses, thanks to orthocyclic winding process ● Control gear can be installed remotely; substantial distance allowed between gear/ignitor & lamp ● Equipped as standard with screw terminal blocks; insert contact on request ● Ea
B1 D1 Type A2Nom B1Nom C1Nom D1Nom 118.0 94.0 61.0 52.0 6.2 BSN 50 118.0 94.0 61.0 52.0 6.2 BSN 100 123.0 98.0 61.0 52.0 6.2 BSN 150 134.0 113.0 76.0 65.0 6.2 BSN 250 160.0 139.0 76.0 65.0 6.2 A1Nom A2Nom B1Nom B2Nom C1Nom D1Nom 166.0 145.0 97.0 78.5 83.0 6.
HID-Basic BSN/BMH semi-parallel ignitor Ordering and packing data Type Weight Qty bulk Dimensions bulk packing packing EAN code EOC bulk packing 8711500 BMH35L407ITS 1.01 6 19.6 cm x 13.3 cm x 11.1 cm 8711500749208 749192 30 BMH70L407ITS 1.1 6 19.6 cm x 13.3 cm x 11.1 cm 8711500061355 739704 30 BSN50L407ITS 0.87 6 19.6 cm x 13.3 cm x 11.1 cm 8711500536129 536129 30 BSN70L407ITS 1.2 6 19.6 cm x 13.3 cm x 11.1 cm 8711500535832 535832 30 BSN100L302I 1.1 6 19.6 cm x 13.
HID Gear HID-Basic BSN/BMH semi-parallel ignitor OEM Catalogue 2009/2010 3.
HID-Basic Multi-Wattage series ignitor Product Description ● Impregnated electromagnetic copper/iron double-wattage gears for use with an external series (superimposed) ignitor for CDO, MH, HPI (Plus) and SON lamps Features and Benefits ● Double wattage & double voltage gears ● Possibility of step-dimming with an external controller ● All gears are equipped with ThermoSwitch protection against endof-lamp-life phenomena ● Compact dimensions and light weight with minimal watt losses, thanks to ortho
B1 D1 Type A2Nom B1Nom C1Nom D1Nom 118.0 94.0 61.0 52.0 6.2 BSN 70/100 123.0 98.0 61.0 52.0 6.2 BSN 100/150 134.0 113.0 76.0 65.0 6.2 A1Nom A2Nom B1Nom B2Nom C1Nom D1Nom 166.0 145.0 97.0 78.5 83.0 6.
HID-HeavyDuty BSN semi-parallel ignitor Product Description ● Encapsulated electromagnetic copper/iron gears for use with an external semi-parallel ignitor for CDM, CDO, MH, HPI (Plus) and SON lamps (no ignitor needed for SON-I lamps) Features and Benefits ● Outstanding product life ● Excellent resistance to chemical attack, humid conditions and high environmental stress crack resistance ● Separate earth terminal ● All gears are equipped with ThermoSwitch protection against endof-lamp-life phenome
B1 D1 Type C1 A2 A1Nom A2Nom B1Nom C1Nom D1Nom BSN 50/70 118.0 103.0 65.0 53.0 6.2 BSN 100 123.0 108.0 65.0 53.0 6.2 BSN 150 L33 126.0 107.5 81.0 66.0 6.2 BSN 150 L34 134.0 115.5 81.0 66.0 6.2 BSN 250 L33 151.0 132.5 81.0 66.0 6.2 BSN 250 L34 160.0 141.5 81.0 66.0 6.2 BSN 400 166.0 147.5 102.0 84.0 6.
HID-HeavyDuty BSN semi-parallel ignitor Electrical installation notes Mechanical installation notes Mains operation Wire cross-section: With tolerances for performance -8% / +6% On the mains side 0.75-2.5 mm2 With tolerances for operation -10% / +10% Strip length 6 mm Operation frequency (typical) 50 Hz Power factor with specified 0.85 capacitor (minimum) BSN 3.
HID Gear HID-HeavyDuty BSN semi-parallel ignitor OEM Catalogue 2009/2010 3.
HID-Basic BHL (HPL/HPI) Product Description ● Impregnated electromagnetic copper/iron gears for HPL and HPI (Plus) lamps Features and Benefits ● Compact dimensions and light weight with minimal watt losses, thanks to orthocyclic winding process ● Equipped as standard with screw terminal blocks; insert contacts on request ● Earthing-while-mounting facility ● Simple installation and cabling ● ThermoSwitch added for maximum safety ● Gears for alternative mains voltages/frequencies on request App
B1 D1 Type C1 A2 A1Nom A2Nom B1Nom C1Nom D1Nom BHL 50 117.0 94.0 61.0 52.0 6.2 BHL 80 117.0 94.0 61.0 52.0 6.2 BHL 125 L202/L307 117.0 94.0 61.0 52.0 6.2 BHL 250 L200/L202 126.0 105.0 76.0 65.0 6.2 BHL 250 L307 134.0 112.0 76.0 65.0 6.2 BHL 400 L200/L202 150.0 130.0 76.0 65.0 6.2 BHL 400 L307 160.0 139.0 76.0 65.0 6.
HID-Basic BHL (HPL/HPI) Ordering and packing data Type Weight Qty bulk Dimensions bulk packing packing EAN code EOC bulk packing 8711500 BHL50L307 0.86 kg 6 19.6 cm x 13.3 cm x 11.1 cm 8711500060891 919076 30 BHL80L307 0.87 kg 6 19.6 cm x 13.3 cm x 11.1 cm 8711500061348 919083 30 BHL125L202 1.05 kg 6 19.6 cm x 13.3 cm x 11.1 cm 8711500060938 919434 31 BHL125L307 1.05 kg 6 19.6 cm x 13.3 cm x 11.1 cm 8711500060921 919090 31 BHL250L200 1.85 kg 6 24.2 cm x 14.1 cm x 13.
HID Gear HID-Basic BHL (HPL/HPI) OEM Catalogue 2009/2010 3.
HID-HeavyDuty BHL (HPL/HPI) Product Description ● Encapsulated electromagnetic copper/iron gears for HPL and HPI (Plus) lamps Features and Benefits ● Outstanding product life ● Excellent resistance to chemical attack, humid conditions and high environmental stress crack resistance ● Compact dimensions and light weight with minimal watt losses, thanks to orthocyclic winding process ● Equipped as standard with screw terminal blocks ● Separate earth terminal (HID ‘Heavy Duty’) ● Simple installati
B1 D1 Type A2Nom B1Nom C1Nom D1Nom 118.0 103.0 65.0 53.0 6.2 BHL 250 L32 134.0 115.5 81.0 66.0 6.2 BHL 250 L40 126.0 107.5 81.0 66.0 6.2 BHL 400 L32 160.0 141.5 81.0 66.0 6.2 BHL 400 L40 151.0 132.5 81.0 66.0 6.2 C1 A2 A1Nom BHL 50/80/125 A1 BHL Electrical data Type Number Rated Power Line Line of Gear- losses Frequency Voltage Lamps Lamp gear (x) Power (W) (Hz) (V) BHL 50/80 L48 230V 50Hz 1 50/80 7.0/10.
HID-HeavyDuty BHL (HPL/HPI) Electrical installation notes Mechanical installation notes Mains operation Wire cross-section: With tolerances for performance -8% / +6% On the mains side 0.75-2.5 mm2 With tolerances for operation -10% / +10% Strip length 6 mm Operation frequency (typical) 50 Hz Power factor with specified 0.85 capacitor (minimum) BHL 50/80, 80, 80/125, 125 3.
HID Gear HID-HeavyDuty BHL (HPL/HPI) OEM Catalogue 2009/2010 3.
HID-HighPower MH, HPI, HPL, SON Product Description ● Encapsulated gears for use with SON (T) (Plus), HPL, HPI and MH lamps with rated wattages of 1000W and above Features and Benefits ● Class I rated (i.e.
HID-HighPower MH, HPI, HPL, SON Type Number Rated Power Line Line of Gear- losses Frequency Voltage Lamps Lamp gear (x) Power (W) (Hz) (V) T-winding Delta-T Input normal current conditions with PF- (ºC) correct. (A) BHL 1000 L02 220V 50Hz 1 1000 40.0 50 220 130 70 5.60 BHL 1000 L78 230/240V 50Hz 1 1000 35.0 50 230/240 130 70 5.40 BSN 1000 L02 220V 50Hz 1 1000 56.0 50 220 130 70 5.70 BSN 1000 L43 220V 60Hz 1 1000 56.0 60 220 130 70 5.
HID-HighPower MH, HPI, HPL, SON SN 56/SN 59 SN 61 SI 52 SI 54 Series ignitor 3.
HID Gear HID-HighPower MH, HPI, HPL, SON OEM Catalogue 2009/2010 3.
HID-Basic gears BSX (SOX) Product Description ● Impregnated electromagnetic copper/iron gears for use with an external ignitor for SOX and SOX-E lamps Features and Benefits ● Compact dimensions and light weight with minimal watt losses, thanks to orthocyclic winding process ● Equipped with double-insert contacts ● Simple installation and cabling ● Gears for alternative mains voltages/frequencies on request Applications ● Ideal for the following applications: ○ Road lighting, railway marshalling
HID-Basic gears BSX (SOX) A2 A3 A1 A4 C3 C1 B2 B1 D1 HID Gear D1 BSX Type A1Nom A2Nom A3Nom A4Nom B1Nom B2Nom C1Nom C3Nom D1Nom 196.0 180.0 54.0 54.0 39.0 20.0 28.0 1.5 4.2 BSX 26/35 + 35/55 Electrical data Type Number Rated Power Line Line of Gear- losses Frequency Voltage Lamps Lamp gear (x) Power (W) (Hz) (V) BSX 26 L80 220V 50Hz 1 26 9.1 50 220 BSX 26 L81 230V 50Hz 1 26 9.4 50 230 BSX 26 L82 240V 50Hz 1 26 9.
HID-HeavyDuty BSX (SOX) Product Description ● Encapsulated electromagnetic copper/iron gears for use with an external ignitor for SOX and SOX-E lamps Features and Benefits ● Outstanding product life ● Excellent resistance to chemical attack, humid conditions and high environmental stress crack resistance ● Compact dimensions and light weight with minimal watt losses, thanks to orthocyclic winding process ● Equipped with screw terminal blocks ● Simple installation and cabling ● Gears for altern
HID-HeavyDuty BSX (SOX) A1Nom A2Nom B1Nom C1Nom D1Nom 118.0 103.0 65.0 53.0 6.2 HID-HeavyDuty BSX 50Hz HD1-118 HID Gear B1 D1 Type C1 A2 A1 BSX Electrical data Type Number Rated Power Line Line of Gear- losses Frequency Voltage Lamps Lamp gear (x) Power (W) (Hz) (V) BSX 35 L40 230V 50Hz 1 35 9.2 50 230 BSX 35/55 L32 240V 50Hz 1 35/55 9.6 50 BSX 90 L32 240V 50Hz 1 90 13.3 50 BSX 90 L40 230V 50Hz 1 90 12.
HID-Constant wattage BSX (SOX) Product Description ● Constant-wattage (potted) electromagnetic copper/iron gears for use with an external ignitor for SOX and SOX-E lamps Features and Benefits ● Compact dimensions and light weight with minimal watt losses, thanks to orthocyclic winding process ● Series capacitor required in circuits with constant-wattage gears ● Equipped with screw terminal blocks ● Simple installation and cabling Applications ● Ideal for the following applications: ○ Road light
Type B2 B1 A1 A2 A2Nom B1Nom B2Nom C1Nom D1Nom 173.0 157.0 64.0 42.0 44.0 4.2 BSX 90 H26 220-230V 50Hz 173.0 157.0 64.0 42.0 52.0 4.2 BSX 91 135 H96 220-240V 50Hz 149.0 135.0 80.0 42.0 67.0 4.2 BSX 131 H96 220-240V 50Hz 178.0 162.0 100.0 42.0 74.0 4.2 BSX 180 H96 220-240V 50Hz 178.0 162.0 100.0 42.0 78.0 4.
HID-Basic ballasts for SON and HPI (plus) lamps with Semi-parallel ignitor Definition Impregnated (HID standard) electromagnetic ballasts, of copper/iron construction, for use in combination with an external ignitor; for HID lamps.
HID-Basic ballasts for SON and HPI (plus) lamps with Semi-parallel ignitor Ballast For lamps Ignitor Mains Without PF Correction With PF correction Ballast Losses Vol./Freq. Current Nom V/Hz A cos Φ Cap. Mains Current Max. Nom. µF/V A. A. Tw= 130°C Wiring Δt diagram Fig. C BSN70L3001 SON 70W SN57 220/50 0.98 0.40 12/250 0.60 0.45 13.5 75 I BSN70L300ITS SON 70W SN57 220/50 0.98 0.40 12/250 0.60 0.45 13.5 75 I BSN70L301I SON 70W SN57 220/60 0.98 0.
HID-Basic ballasts for SON and HPI (plus) lamps with Semi-parallel ignitor Marking “designed by Philips Lighting B.V. , the Netherlands” Ordering and packing data Type Weight Carton packing Carton packing Weight Pallet unit Qty Dimensions gross carton/pcs EOC pcs l x w x h cm kg 1.1 6 18.2 x 12.5 x 13.3 7 630 871016303161330 BSN100L300I 1.2 6 18.2 x 12.5 x 13.3 7.5 630 871016303151430 BSN150L300I 1.85 6 26.0 x 15.0 x 16.1 11.5 504 871016303088330 BSN250L300I 4.5 4 26.
HID-Basic ballasts for SON and HPI (plus) lamps with Semi-parallel ignitor Marking “Made in China” Type Weight Carton packing Carton packing Weight Pallet unit Qty Dimensions gross carton/pcs EOC pcs l x w x h cm kg 1.1 6 18.2 x 12.5 x 13.3 7 630 871016303160630 BSN100L300I 1.2 6 18.2 x 12.5 x 13.3 7.5 630 871016303150730 BSN150L300I 1.85 6 26.0 x 15.0 x 16.1 11.5 504 871016303087630 BSN250L300I 4.5 4 26.0 x 17.5 x 16.1 16.5 288 871016303090630 22.6 x 19.0 x 19.
HID -Basic ballasts for HPL, HPI (plus) lamps Definition Impregnated (HID standard) electromagnetic ballasts, of copper/ iron construction, for use in combination with an external ignitor, for HID lamps. Description ● Orthocyclic winding process results in limited ballast coil volume and reduced weight, with minimum watt losses ● Ballasts standard equipped with screw terminal blocks ● Earthing while-mounting facility (HID Standard ballasts) ● Simple installation and cabling.
HID -Basic ballasts for HPL, HPI (plus) lamps Ballast For lamps Ignitor Mains Without PF Correction With PF correction Ballast Losses Vol./Freq. Current Nom V/Hz A cos Φ Cap. Mains Current Max. Nom. µF/V A. A. Tw= 130°C Wiring Δt diagram Fig. C BHL 125L200 HPL 125W N.A. 220/50 1.15 0,55 10/250 1,1 0,7 12,2 70 1 BHL 125L202 HPL 125W N.A. 230/50 1.15 0,55 10/250 1,1 0,7 13,0 70 1 BHL 125L204 HPL 125W N.A. 240/50 1.
HID -Basic ballasts for HPL, HPI (plus) lamps Marking “designed by Philips Lighting B.V. , the Netherlands” Ordering and packing data Type Weight Carton packing Carton packing Weight Pallet unit Qty Dimensions gross carton/pcs EOC pcs l x w x h cm kg BHL125L200 1.2 6 18.2 x 12.5 x 13.3 9 630 871016303168230 BHL250L200 1.85 6 27.0 x 16.0 x 17.0 12.76 504 871016303097530 BHL400L200 2.9 6 26.0 x 17.5 x 16.1 17.8 288 871016303100230 BHL250L201 1.9 6 26.0 x 15.0 x 16.
HID Lamps HID -Basic ballasts for HPL, HPI (plus) lamps OEM Catalogue 2009/2010 3.
HID ignitors Product Description ● Electronic ignitors for HID lamps Features and Benefits ● Available in semi-parallel (Pulse), series (Superimposed pulse) and parallel versions ● Ignitors ensure reliable and smooth starting behaviour ● Ignitors equipped as standard with screw terminal blocks ● Digital ignitors for highest reliability ● All T5 and T15 types incorporate timer to switch off ignitor after 5 or 15 minutes with failing lamp to prevent cycling ● Compact dimensions and light weight
HID ignitors B1 SI 51 / SI 52 / SN 57 / SN 57T5 / SN 57T15 / A1Nom A2Nom B1Nom C1Nom D1Nom 84.5 65.0 41.0 38.0 4.3 85.5 - 41.5 38.5 - A1Nom A2Nom B1Nom C1Nom D1Nom 89.0 70.0 41.5 38.5 4.3 A1Nom A2Nom B1Nom C1Nom D1Nom 114.5 95.0 41.0 38.0 4.
HID ignitors Electrical data Type Number Rated Power Line Line Response T-case of Gear- losses Frequency Voltage voltage maximum Lamps Lamp gear T-ambient Ignition Number Voltage of ignition Cable-Cap wires pulses device/lamp (x) Power (W) (Hz) (V) (V) (ºC) (kV) (x) (nF) SI 51 220-240V 1 250/400 1.0 50/60 220-240 190 80 -20/75 0.75 1 150 SI 51-S 220-240V 1 1000 1.0 50/60 220-240 190 80 -20/75 0.75 1 150 SI 52 220-240V 1 250/400 1.
HID ignitors Type EAN code Weight 1 piece Qty bulk Dimensions bulk packing packing EAN code EOC bulk packing 8711500 SI 51 220-240V 50/60Hz 8711500915535 0.047 kg 48 25.2 cm x 18 cm x 17.4 cm 8711500908353 915535 30 SI 51-S 220-240V 50/60Hz 8711500747495 0.051 kg 20 20 cm x 17.5 cm x 11 cm 8711500747501 747495 30 SI 52 220-240V 50/60Hz 8711500915542 0.06 kg 48 25.2 cm x 18 cm x 17.4 cm 8711500908377 915542 30 SI 54 360-415V 50/60Hz 8711500915481 0.083 kg 20 23.5 cm x 22.
HID ignitors SI 52 SN 50/56/57/57-S/58/58-S/59 SU/SUD SX 70/72/74/76 SX 131/73 SN 61 SND SI 51/51-S/54 3.
HID Gear HID ignitors OEM Catalogue 2009/2010 3.
Recommended HID Lamp and Gear combination Lamp Electronic solution Commercial name Technical name MASTER CosmoWhite CPO-TW CPO-TW 45W CPO-TW 60W CPO-TW 90W CPO-TW 140W MASTER Colour City CDO-T(T)/ET CDO 70W CDO 100W CDO 150W MASTER SON-T PIA PLUS MASTER SON PIA PLUS MASTER SON-T PIA SON 50W SON 70W SON 100W SON 150W SON 250W SON 400W SON 600W SON 600W-400V SON 1000W SON-I SON-I 50W SON-I 70W SON-H SON-H 110W SON-H 220W SON-H 350W MASTER HPI PLUS HPI PLUS 250W BU HPI PLUS 400W BU HPI PLUS 400
Recommended HID Lamp and Gear combination Electro-magnetic solution Ignitor Capacitor BSN 70 TS BSN 100 TS BSN 150 TS SN(D) 57 SN(D) 58 SN(D) 58 12uF/250V 12uF/250V 18uF/250V BSN 50 BSN 70 BSN 100 BSN 150 BSN 250 BSN 400 BSN 600 TS BSN 600 L 309 ITS BSN 1000 SN(D) 57 SN(D) 57 SN(D) 58 SN(D) 58 SN(D) 58 SN(D) 58 SN(D) 58 SND 88 / SND 89 SN 56 / SN 59 10uF/250V 12uF/250V 12uF/250V 18uF/250V 32uF/250V 45uF/250V 60uF/250V 20uF/450V 100uF/250V BSN 50 BSN 70 - 10uF/250V 12uF/250V BHL 125 BHL 250 BHL 4