Technical data

52
UK
073 Alarm behaviour for internal (C)
To change the alarm property for internal active (C):
1. On the control unit, enter:
073
2. The LCD display shows: 073: C = Internal
3. Via the keypad, select from the following items
and press:
0
C=Keypad
Only the control units are activated.
1
C=Internal
On alarm, the control units and the
internal alarm are activated.
2
C=Local
On alarm, the control units, the internal
alarm and the external siren are
activated.
3
C=Full
On alarm, the control units, the internal
signalling, the external sirens and the
exits are activated.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
075 Exit delay time internal C
To change the property of the exit delay time for internal
active C:
1. On the control unit, enter:
075
2. The LCD display shows: 075: E C=10
3. Via the keypad, select from the following items
and press:
1
Exit C=10
Exit delay time for internal active C is
10 seconds.
2
Exit C=20
Exit delay time for internal active C is
20 seconds.
3
Exit C=30
Exit delay time for internal active C is
30 seconds.
4
Exit C=45
Exit delay time for internal active C is
45 seconds.
5
Exit C=60
Exit delay time for internal active C is
60 seconds.
6
Exit C=120
Exit delay time for internal active C is
120 seconds.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer mode.
076 Behaviour of exit mode internal (D)
To change the property of the exit mode for internal active
(D):
1. On the control unit, enter:
076
2. The LCD display shows: 076: D=Low Tone
3. Via the keypad, select from the following items
and press:
0
D=Low Tone
The acoustic signal during the exit
delay time is emitted at half volume.
1
D=Instant
During internal activation, the alarm
centre is internally activated
immediately – i.e., without delay.
2
D=Silent
No acoustic signal is emitted during the
delay time. Following expiry of the delay
time, the alarm centre emits a brief
signal.
3
D=A
The initial mode for internal active B is
as for the initial mode of overall active A
4. Confirm your input. On the control unit, enter:
.