Operation Manual

ā€“ 11 ā€“
This appliance must be earthed (information for UK only).
How to change a fuse:
This apparatus is supplied with an approved moulded 13A plug. To change a fuse in this type of plug
proceed as follows:
1. Remove fuse cover and fuse.
2. Fit new fuse which should be a BS 1362 5A, A.S.T.A. or BSI approved type.
3. Refit the fuse cover.
If the fitted plug is not suitable for your socket outlets, it should be cut off
and an appropriate 3-pin plug fitted in its place.
If the mains plug contains a fuse, this should have a value of 5A. If a plug
without a fuse is used, the fuse at the distribution board should not be
greater than 5A.
The severed plug must be destroyed to avoid a possible shock hazard should it be inserted
into a 13A socket elsewhere.
How to connect a plug:
The wires in the mains lead are coloured in accordance with the following code:
BLUE - "NEUTRAL" ("N")
BROWN - "LIVE" ("L")
GREEN & YELLOW - "EARTH" ("E")
1. The GREEN & YELLOW wire must be connected to the terminal in the
plug which is marked with the letter "E" or by the Earth symbol or coloured
GREEN AND YELLOW.
2. The BLUE wire must be connected to the terminal which is marked with
the letter "N" or coloured BLACK.
3. The BROWN wire must be connected to the terminal which is marked
with the letter "Lā€œ or coloured RED.
Before replacing plug cover, make certain that the cord grip is clamped over the sheath of the lead - not
simply over the three wires.