User manual

Brush head
1 Rinse the brush head and bristles after each use.
2 Remove the brush head from the handle and rinse the brush head connection at least once
a week with warm water.
Charger
1 Unplug the charger before cleaning.
2 Use a damp cloth to wipe the surface of the charger.
Sanitizer (select models)
Do not clean the sanitizer when the UV light bulb is hot.
For optimal effectiveness, it is recommended to clean your sanitizer weekly.
1 Unplug the sanitizer.
2 Slightly lift the drip tray and pull it out. Rinse the drip tray and wipe it clean with a damp
cloth.
3 Clean all reector surfaces with a damp cloth.
4 Remove the protective screen in front of the UV light bulb.
To remove the screen, gently lift it up (1) and pull it out (2).
5 Remove the UV light bulb.
To remove the light bulb, grasp it and pull it out of the metal clasp.
6 Clean the protective screen and the UV light bulb with a damp cloth.
7 Reinsert the UV light bulb.
To reinsert the light bulb, align the bottom of the light bulb with the metal clasp and push the bulb
into the clasp.
8 Reinsert the protective screen.
To reinsert the screen, align the pegs on the screen with the slots on the reective surface near
the UV light bulb. Then insert the pegs into the slots and slide down the screen to secure it in the
sanitizer.
Storage
- If you are not going to use the product for an extended period of time, unplug it from the
electrical outlet, clean it and store it in a cool and dry place away from direct sunlight. You can
use the cord wrap (select models) to store the power cord in an organized manner.
- You can store brush heads on the pegs at the back of the charger.
Replacement
Brush head
- Replace Sonicare brush heads every 3 months to achieve optimal results.
- Use only compatible Sonicare replacement brush heads.
UV light bulb
- Replacement UV bulbs are available through your Sonicare Consumer Care Center in North
America by calling 1-800-682-7664. Outside North America, contact your local Philips
Consumer Care Center.
Disposal
- At the end of product life and prior to disposal, please remove the rechargeable battery from
the handle by following the instructions below.
ENGLISH10