Owner’s Manual & Warranty Models SPP 00WA/ 7 / SPP 0WA/ 7 / SPP 0WA/ 7
Introduction Thank you for choosing Philips model SPP4200 / SPP4210 / SPP4220 Theatre DirectorTM Advanced Surge Protector. With Theatre Director, the home theater surge protector is moved off the floor behind the A/V cabinet up to the shelf or rack that holds all of the other components. This provides the ultimate in convenience when connecting all of the components. In addition to the convenience, Theatre Director is also technologically superior to standard surge protectors.
V3TM Technology For the more common everyday transient surges and spikes that are most commonly caused by household appliances turning on and off, Theatre Director uses an advanced type of MOV (metal oxide varistor). This new type of MOV provides greater capacity to absorb surges and spikes, as well as better energy dissipation. The result is a more efficient, longer lasting surge protector.
RJ11 Modem/Phone Line Protection As with incoming coaxial or RJ45 networking lines, surges can also enter your system through standard RJ11 phone lines. Some A/V components, such as digital satellite receivers, DVRs, TiVoTM, etc., require connection to a phone line. Theatre Director will protect your equipment from surges coming through this line too. In addition, should your system incorporate more than one component that requires a phone line connection, we included a 1-in / 2-out phone line splitter.
Feature Chart Model SPP4200 SPP4210 SPP4220 s-OV Technology √ √ √ V3TM Technology √ √ √ ClearConnect Technology √ √ √ Always-on AC Outlets 2 2 2 Switched AC Outlets 6 8 10 Total AC Outlets 8 10 12 Coaxial Cable Protection 2 sets 3 sets 4 sets RJ45 Network Protection n/a √ √ RJ11 Modem/Phone Protection √ √ √ Grounding Lug √ √ √ Resettable Circuit Breaker √ √ √
Front Panel Indicators A series of intelligent LED indicators on the front panel of Theatre Director keep you informed of the power status at all times. The red light lets you know that the surge protection function is ready in the event it is needed. The green light lets you know that your electrical system is wired and grounded properly. The range of blue lights let you know what your current input voltage level is.
Specifications Model Maximum Input Voltage (VAC) Nominal Input Frequency (Hz) Maximum Output Power (Watts) Maximum Line Current (Amps) AC Line Clamping Voltage Energy Dissipation (Joules) EMI/RFI Noise Filtering (dB) SPP4200 SPP4210 125 60 1875 15 330 5400 85 SPP4220 Maximum Transient Current (Amps; all lines) 288,000 360,000 432,000 <1 <1 <1 4320 Transient Response Time (nanoseconds) Power Cord Length Coax Clamping Voltage 8ft. 75 Coax Attenuation <1.0dB to 2.
Warnings TO PREVENT THE RISK OF ELECTRICAL SHOCK OR FIRE: • This product is designed for indoor use only. • Do not use in wet or damp areas exposed to moisture. • N ot recommended for use with aquariums. High humidity environments can cause corrosion and surface contamination, which may result in heat buildup and/or arcing between plug blades. • Device must be properly connected to a grounded three-prong receptacle. • Do not daisy chain the unit with another extension cord or multiple outlet device.
Connected Equipment Warranty The Customer’s exclusive remedy under any warranty, including this express Connected Equipment Warranty or any applicable implied warranty, and Philips’ sole obligations, are as follows for “Connected Equipment”: If, (a) the Product purchased and owned by the Customer is defective in materials or workmanship under the Limited Product Warranty, or any applicable implied warranty; (b) the stated Limited Product Warranty requirements have been met; and (c) none of the limitations o
Agreed Damage Amount The Agreed Damage Amount for all items of the Customer’s Connected Equipment shall be the lesser of the amount determined under clause (a) or (b) below, reduced by any amounts described in clause (c) below. a) T he fair market value of the equipment shall be the current value of the equipment specified in the most recent edition of Orion Blue Book (by Orion Research Corporation, Roger Rohrs Publisher) or a valuation as determined by Philips in its reasonable discretion.
OTHER EXCLUSIONS Philips does not cover or undertake liability in any event for any of the following: 1. L oss of or damage to data, records or software; restoration of data or records; or re-installation of software. 2. A ny amount of money that the Customer may recover from other sources regarding the Connected Equipment Warranty; including insurance, other warranty or extended warranty coverage.
Philips 1881 Route 46 West Ledgewood, NJ 07852 800-852-4312 www.Philips.