PSW-H Installation and User Manual

www.phocos.com 27 | P a g e
UPS (Default)
Accepted AC input voltage range
from 170 ~ 280 Vac for 230 Vac
models, 90 ~ 140 Vac for 120 Vac
models.
05
Battery type
Settings menus 26, 27 and 29
can only be modified if “User-
defined” is selected here.
Please visit www.phocos.com
for a current list of (Lithium)
batteries supported and their
specific settings guides.
CAUTION: Do not use
inverter communication
cables supplied with your
batteries unless instructed
by Phocos guides as this
may damage the PSW-H
and/or the battery!
AGM (Default)
Flooded
User-defined
Battery charging voltages and low
voltage disconnect (LVD) can be
manually defined in settings menu
26, 27 and 29.
Pylontech battery
For use with Pylontech Lithium
batteries. Ensure the battery
management system (BMS)
communication is connected.
WeCo battery
For use with WeCo Lithium
batteries. Ensure the battery
management system (BMS)
communication is connected.
RS-485 (MODBUS RTU) battery
For use with Lithium batteries
using the Phocos MODBUS RTU
communication protocol. Ensure
the battery management system
(BMS) communication is
connected.
06
Automatic restart if an AC
output overload occurs
Restart disabled (Default)
Restart enabled
07
Automatic restart when over-
temperature occurs
Restart disabled (Default)
Restart enabled
08
Solar power feed-in into grid
A PIN code is required to
change this setting. Grid feed-
in / injection may not be legal
at the site of installation.
Contact your dealer for more
details.
Only activate when using the
public grid as AC source, else
your AC generator and the
Any-Grid could be damaged.
Disabled (Default)
Enabled