PSW-H Installation and User Manual

www.phocos.com 32 | P a g e
34
Battery equalization voltage
59.2 Vdc (48 Vdc model Default)
29.6 Vdc (24 Vdc model Default)
Available values: 48.0 ~ 64.0 Vdc in
0.1 Vdc increments for 48 Vdc
model.
Available values: 24.0 ~ 32.0 Vdc in
0.1 Vdc increments for 24 Vdc
model.
35
Battery equalization duration
The duration for which the
equalization voltage from
settings menu 34 is held
before the Floating phase is
reached.
120 min. (Default)
Available values: 5 ~ 900 minutes in
5 min. increments.
36
Battery equalization timeout
If the equalization voltage
from settings menu 34 cannot
be reached within the
duration from settings menu
35, once this timeout is
reached, equalization is ended
and the charger returns to
Floating phase.
180 min. (Default)
Available values: 5 ~ 900 minutes in
5 min. increments.
37
Equalization interval
30 days (Default)
Available values: 0 ~ 90 days in 1-
day increments.
39
Equalization phase: forced
start
Enabled
Disabled (Default)
If the battery equalization function is enabled in settings menu 33, this
function can be enabled. If “Enabled” is selected in this menu, battery
equalization is immediately force-started and the display main view
will show
(EQ).
If “Disabled” is selected, it will cancel the forced equalization function
until the next scheduled equalization interval as defined in settings
menu 37. will no longer be shown in LCD main page.
40
Reset PV and Load energy
datalogger storage
Not reset (Default)
Reset