User manual
common rectifier type diode (1A, 200V rating), in parallel with the relay coil (see below).
3. Operation
3-1. Turning on inverter
Change the DIP switch setting to the mode you wish first, then turn the inverter on. The
buzzer beeps twice, LED shows green -> orange -> red -> green sequence. The inverter
is now ready to deliver AC power to your loads.
If there are several loads in use, turn them on separately after the inverter has been
turned “ON” in order to prevent the OVP caused by the power surge.
3-2. Turning off inverter
Set the main switch to the OFF position, the inverter output turns off and the LED goes off.
3-3. Remote controller operation
Make sure the main switch is in the “off” position.
Connect the remote controller to the inverter.
Turn the main switch to remote control position.
Turn the remote switch “on” or “off” to control the inverter operation or not.
23
ENG
Wiring diagram for a PV system using charge controllers