Datasheet

https://www.phoenixcontact.com/gb/products/1064922
06/18/2019Page3/6
Power supply unit-EM-CPS-PS/3AC/24DC/5-1064922
Technical data
Output data
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple
≤ 20 mV
PP
Output power 120 W
Typical response time < 1 s
Maximum power dissipation in no-load condition < 1 W (400 V AC)
Power loss nominal load max. < 12 W (480 V AC)
General
Net weight 0.7 kg
Efficiency typ. 91 % (400 V AC)
Insulation voltage input/output 3 kV AC (type test)
1.5 kV AC (routine test)
Protection class II (in closed control cabinet)
Degree of protection IP20
MTBF (IEC 61709, SN 29500) > 2300000 h (25°C)
> 1300000 h (40°C)
> 620000 h (60 °C)
Assembly instructions Cross Power System
Connection data, input
Connection method Snap-on connection
Connection data, output
Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 10 mm
Connection data for signaling
Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm