Datasheet

https://www.phoenixcontact.com/gb/products/1409060
06/08/2015Page2/7
DC charging cable-EV-T2M4CC-DC125A-5,0M50ESBK00-1409060
Technical data
Technical properties
Type of signal transmission Pulse width modulation
Temperature monitoring 2x Pt 1000
Number of power contacts 3 (PE, DC+, DC-)
Number of signal contacts 2 (CP, PP)
Connection method Crimp connection, cannot be separated
Contact material Cu
Contact surface material Ag
Resistor coding 1500 Ω (between PE and PP)
Insertion force < 100 N
Withdrawal force < 100 N
Insertion/withdrawal cycles > 10000
Ambient temperature (operation) -30 °C ... 50 °C (Operation)
Ambient temperature (storage/transport) -40 °C ... 80 °C (Storage)
Altitude difference for area of application 5000 m (above sea level)
Degree of protection IP44 (plugged in)
IP20 (not plugged in, IP24 should be ensured by the charging station)
Label 14.1 mm x 44.8 mm (customer logo possible)
Cable
Cable structure 2 x 50 mm² + 1 x 25 mm² + 3 x 2 x 0.75 mm² (EN 60228 class 6)
External cable diameter 28.2 mm ±0.2 mm
Type of conductor straight
Outer sheath, material HFFR
External sheath, color black
Minimum bending radius 140 mm (5 x diameter)
Temperature monitoring
Type of sensor Pt 1000
Standards/regulations DIN EN 60751
Recommended measured current 1 mA (1 V at 0°C)
Tolerance at the sensor with the recommended measured current  1K
Temperature range -50 °C ... 130 °C
Temperature coefficient (TCR) 3850 ppm/K
Long-term stability (max. R0-Drift) 0.06 % (After 1000 hours at 130°C)
Classifications
eCl@ss
eCl@ss 4.0 272607xx
eCl@ss 4.1 27260701
eCl@ss 5.0 27260701
eCl@ss 5.1 27260701