Datasheet

https://www.phoenixcontact.com/us/products/1503425
May 23, 20162/8
Sensor/actuator box-SACB- 6/3-L-C-M8-1503425
Technical data
Master cable data/connection data
Conductor cross section min. (signal)
0.14 mm²
Conductor cross section max. (signal)
1.5 mm²
Conductor cross section AWG min. (signal)
26
Conductor cross section AWG max. (signal)
16
Stripping length (signal)
7 mm
Conductor cross section min. (energy)
0.14 mm²
Conductor cross section max. (energy)
1.5 mm²
Conductor cross section AWG min. (energy)
26
Conductor cross section AWG max. (energy)
16
External cable diameter min.
7 mm
External cable diameter max.
12 mm
Stripping length
60 mm (Master cable)
Tightening torque, cover screw
1 Nm
Tightening torque, union nut
2.5 Nm
Tightening torque slot sensor/actuator cable
0.2 Nm
Insulation material
Housing material
PBT
Material of the moulding mass
PUR
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA
Material of contact, master cable side
CU alloy
Material of contact surface, master cable side
Gold-plated
Material of the contact carrier on the master cable side
PA 66 V0
Material of threaded sleeve
Cu alloy
Material of threaded sleeve surface
Nickel-plated
O-ring material
NBR
Pin assignment
Slot/position = Wire color or connection
1 / 4 (A)=1 / 4
Slot/position = Wire color or connection
2 / 4 (A)=2 / 4
Slot/position = Wire color or connection
3 / 4 (A)=3 / 4
Slot/position = Wire color or connection
4 / 4 (A)=4 / 4
Slot/position = Wire color or connection
5 / 4 (A)=5 / 4
Slot/position = Wire color or connection
6 / 4 (A)=6 / 4
Slot/position = Wire color or connection
1-6 / 1 (+ 24 V)=U
N
Slot/position = Wire color or connection
1-6 / 3 (0 V)=0 V
Standards and Regulations
Standard designation
M8 connector
Standards/regulations
IEC61076-2-104
Connection in acc. with standard
CUL