Datasheet

https://www.phoenixcontact.com/us/produkte/1584075
Nov 12, 20131/11
Contact insert-HC-DD72-I-CT-M-1584075
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in
the user's documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
HEAVYCON male insert, DD72 series, 72-pos., crimp connection. PE connection using tension
sleeve technology.
Key commercial data
package_quantity
10
GTIN
4046356133388
Technical data
General
Note
For HEAVYCON ADVANCE and HEAVYCON housing of B16
type, crimp contacts CK 1,6-ED (crimp contacts not included in the
scope of supply). Plug-in connections may only be operated only
when there is no load/voltage.
Connection method
Crimp connection
Pollution degree
3
Surge voltage category
III
Constructional and testing regulations
DIN VDE 0627/86
Constructional and testing regulations
DIN VDE 0110/02.79
Constructional and testing regulations
DIN VDE 0110-1/04.97
Constructional and testing regulations
IEC 60664-1, DIN IEC 60512
Constructional and testing regulations
IEC 60352
Number of positions
72+PE
Insertion/withdrawal cycles
≥ 500
Design
B16
Connection in acc. with standard
IEC / EN
Conductor cross section
0.14 mm² ... 2.5 mm²
Connection cross section AWG
26 ... 14
Stripping length of the individual wire
8 mm (6 mm (2.5 mm²))
Stripping length of the individual wire
6 mm (2.5 mm²)
Assembly instructions
-Housing heights with h >= 72 mm are recommended in the case
of a large number of wires.-Use of HC-CST (1676857) coding pins
and HC-CBU (1676860) coding sockets has been prescribed.
Connection
Connectors may be plugged in only when there is no load/voltage.
Ambient conditions
Ambient temperature (operation)
-40 °C ... 125 °C (including heating up of contacts)