Socket Outlet-EV-T2M3SE12-3AC32A-0,7M6,0E00-1621729
Technical data
Dimensions
Conductor length
0.5 m (Locking actuator cables)
Cable structure
5x 6.0 mm² + 2x 0.5 mm²
Type of conductor
Single wires
Ambient conditions
Ambient temperature (operation)
-30 °C ... 50 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Max. altitude
5000 m (above sea level)
Degree of protection
IP44 (plugged in)
Degree of protection
IP54 (with hinged cover, see accessories)
Electrical properties
Maximum charging power
22 kW
Number of phases
3
Number of power contacts
5 (L1, L2, L3, N, PE)
Rated current of power contacts
32 A
Rated voltage for power contacts
480 V AC
Number of signal contacts
2 (CP, PP)
Rated current for signal contacts
2 A
Rated voltage for signal contacts
30 V AC
Type of signal transmission
Pulse width modulation
Mechanical properties
Insertion/withdrawal cycles
> 10000
Insertion force
< 100 N
Withdrawal force
< 100 N
Mounting
Possible mounting positions
Front and rear mounting
Restrictions to mounting position
Only 0 to 90 degree frontal inclination possible, see figure
Mounting position of the locking actuator
Not pre-assembled, top center mounting possible
Screw connection of a hinged cover
Only rear mounting possible
Max. wall thickness
max. 50 mm (Rear panel mounting, normative maximum
specification for infrastructure plug)
Max. wall thickness
max. 28 mm (Rear panel mounting, normative maximum
specification for infrastructure plug when using the hinged cover
1405217)
Max. wall thickness
max. 10 mm (Front mounting, when using the locking mechanism)
Mounting hole diameter
7.00 mm (ø)
Design
Design line
Standard
Housing color
black
Customer variations
On request
Material