Datasheet

https://www.phoenixcontact.com/us/products/1622176
12/16/2016Page5/11
Socket Outlet-EV-T2M3SE12-3AC32A-1,5M6,0E10-1622176
Schematic diagram
Rear mounting with rear hinged cover screw connection
The screw connection for a hinged cover from the accessories range (EV-
T2SC) only supports rear mounting. The panel thickness must not exceed 5
mm. The sealing frame that is slid on from the rear must contact the housing
wall flush with the flat side and must completely surround the Infrastructure
Socket Outlet.
Schematic diagram
Front mounting with rear hinged cover screw connection
Front mounting is only possible when the locking actuator is removed. We
recommend using an Infrastructure Socket Outlet without pre-assembled
locking actuator (EV-T2M3SE-…E0..., e.g., 1621729).
The screw connection for a hinged cover from the accessories range (EV-
T2SC) only supports rear mounting. The panel thickness must not exceed
10 mm. The sealing frame that is slid on from the front must contact the
housing wall flush with the flat side and must completely surround the
Infrastructure Socket Outlet.