Datasheet

https://www.phoenixcontact.com/us/produkte/1648157
Nov 12, 20131/12
Contact insert-HC-B 6-I-CT-M-1648157
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in
the user's documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
HEAVYCON male insert, B6 series, 6-pos., for crimp contacts. PE connection using tension sleeve
technology.
Product Features
For fast coding with plastic profile
PE connection using tension sleeve technology
Key commercial data
package_quantity
10
GTIN
4046356092272
Technical data
General
Note
For HEAVYCON ADVANCE and HEAVYCON housing of B6 type,
crimp contacts CK 2,5-ED (crimp contacts not included in the
scope of supply).
Connection method
Crimp connection
Pollution degree
3
Surge voltage category
III
Constructional and testing regulations
DIN EN 61984
Constructional and testing regulations
DIN EN 60664
Constructional and testing regulations
IEC 60352
Number of positions
6+PE
Insertion/withdrawal cycles
≥ 500
Design
B6
Connection in acc. with standard
IEC / EN
Conductor cross section
0.5 mm² ... 4 mm²
Connection cross section AWG
20 ... 12
Stripping length of the individual wire
7.5 mm
Assembly instructions
Coding also using the CP-HC (1686478) coding profiles. HC-B6../
HC-B10..for two coding profiles. HC-B16../ HC-B24..for four coding
profiles.
Connection
For housing design B6. Connectors may only be inserted when
there is no load/the power is switched off. Use a screwdriver to
remove the crimp contacts. The opening for the screwdriver is next
to the opening where the conductor is inserted.