User manual
PHOENIX CONTACT GmbH & Co. KG
D-32823 Blomberg, Germany
Fax: +49 52 35 3-4 12 00
Phone: +49 52 35 3-00
www.phoenixcontact.com
EN
Fig. 1
98
7
Fig. 2
30
Fig. 3
4
Fig. 4
5
4
Fig. 5
Fig. 6
24
31
Fig. 7
1
7
6
Fig. 8
9
8
7
Installation instructions
VARIOSUB RJ45 QUICKON
Type Order No.
Plug connector
VS-08-RJ45-5-Q/IP67 1656990
Accessories:
Marker label set
VS-ZBFM-8-SET 0814775
Table 1: Connection in acc. with TIA 568
TIA 568 A TIA 568 B Profinet
PIN Color Color Color
1 White/green White/orange Yellow
2 Green Orange Orange
3 White/orange White/green White
4 Blue Blue –
5 White/blue White/blue –
6 Orange Green Blue
7 White/brown White/brown –
8 Brown Brown –
Connector pin assignment
The color coding printed on the plug insert
corresponds to TIA 568-A!
6
3
2
1
8
7
4
5
Technical data
Transmission properties
CAT5 in acc. with IEC 11801:2002/ EN
50173:2002; CAT5e in acc. with TIA 568-B:2001
No. of pos.
8
Degree of protection
IP67
Inflammability class in acc. with UL 94
V0
Insertion/withdrawal cycles
>1000
Temperature ranges
Storage temperature
-40 °C ... 70 °C
Operating temperature
-20 °C ... 70 °C
Triggering temperature
-10 °C ... 60 °C
Conductor cross section
Solid conductors (1-wire)
AWG 26 ... 22 / 0.13 ... 0.32 mm
2
Stranded conductors (7-wire)
AWG 26 ... 22 / 0.14 ... 0.36 mm
2
Cable diameter
5.0 ... 8.0 mm
Connection method
IDC / insulation displacement contacts in acc. with
IEC 60352-4
MNR. 0061229/17.08.06-02 Printed in Germany ©PHOENIX CONTACT 2006
Assembly
The plug connector can be used for cables with an
external diameter of 5.0 ... 8.0 mm and a core cross
section of AWG 26 ... 22 (stranded and solid
conductors). The diameter of the core insulation must
not exceed 1.6 mm! The plug connector can be
reconnected up to 20 times over (only with the same
core cross section).
1. First slide the pressure nut
9, the cable seal 8
and the rear part of the housing
7 over the cable
(fig. 1).
2. Strip the cable sheath over a length of 30 mm. Fold
back the braided shield over the cable sheath. Trim
the braided shield to a length of approx. 8 mm and
fix it with the enclosed adhesive shielding foil
(fig. 2).
3. Untwist the twisted pairs and arrange the cores
according to the imprinted color coding.
4. Remove the termination blocks
5 from the plug
insert
4.
5. Slightly separate the shielding lugs and then slide
the plug insert
4 onto the cable. Press the shiel-
ding lugs together so that they make contact with
the adhesive shielding foil (fig. 3). This prevents the
plug from slipping back when the cores are being
connected.
6. Guide the individual cores into the chambers and
trim the cores according to fig. 3 using a small
diagonal cutter. For Profinet applications, see table 1
for the core assignment. Plug the termination
blocks
5 into the plug insert 4 according to
fig. 4.
7. Contact the cores by pressing the termination
blocks
5 together (fig. 5).
Alternatively, standard pliers can be used.
8. Slide the front part of the housing
1 as far as it will
go into the plug insert
4. Ensure that the marker
groove
2 and locking clip 3 are opposite one
another (fig. 6).
9. Slide the rear part of the housing
7 into the
front part of the housing
1 and ensure that the
engagement nose
6 snaps in completely (fig. 7).
10. Push the cable seal
8 as far as it will go into the
clamping cage of the rear part of the housing
7.
Tighten the pressure nut
9 firmly by hand (fig. 8).
Ø18,5
38,4
11
22,8
77
Dimensions: VS-08-RJ45-5-Q/IP67
1
Front part of the housing
6
Engagement nose
2
Marker groove
7
Rear part of the housing
3
Locking clip
8
Cable seal
4
Plug insert
9
Pressure nut
5
Termination block
12 34 6 7 8 95