Insulation resistance ≥ 100 MΩ
Length of cable 3 m
Ambient temperature (operation) -25 °C ... 90 °C (Male connector / female connector)
General characteristics
Standards/regulations M12 connector IEC 61076-2-101
Coding A - standard
Surge voltage category II
Pollution degree 3
Degree of protection IP65/IP68/IP69K
Insertion/withdrawal cycles ≥ 100
Torque 0.4 Nm (M12 connector)
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material TPU GF
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Zinc die-cast, nickel-plated
Sealing material NBR
Status display No
Conductor data
Cable type PUR halogen-free black
Cable type (abbreviation) PUR
UL AWM Style 20549
Conductor cross section 5x 0.34 mm² (signal line)
AWG signal line 22
Conductor structure signal line 42x 0.10 mm
Core diameter including insulation 1.27 mm ±0.02 mm (signal line)
Thickness, insulation Approx. 0.7 mm
External cable diameter 5 mm ±0.15 mm
Wire colors brown, white, blue, black, green-yellow
External sheath, color Black-gray RAL 7021
Insulation resistance ≥ 16 GΩ*km (at 20 °C)
Conductor resistance max. 58 Ω/km (at 20 °C)
Nominal voltage, conductor 300 V
Test voltage, conductor 3000 V