Brochure

No. of pos. Dim. a
[mm]
2 3.50
3 7.00
4 10.50
5 14.00
6 17.50
7 21.00
8 24.50
9 28.00
10 31.50
11 35.00
12 38.50
13 42.00
14 45.50
15 49.00
16 52.50
2 3.81
3 7.62
4 11.43
5 15.24
6 19.05
7 22.86
8 26.67
9 30.48
10 34.29
11 38.10
12 41.91
76 PHOENIX CONTACT
Notes:
In order to avoid tolerances between the terminal blocks and PCB,
the terminal row should be interrupted when the number of posi-
tions exceeds 30.
1
) Please observe the current carrying capacity curves. Other cur-
rent carrying capacity curves are available on request.
PCB terminal blocks with extremely
compact housing dimensions with 3.5 or
3.81 mm pitch
MKDS 1/...
Single-row type with horizontal connec-
tion direction
SMKDS 1/ .
Conductor and screwdriver axis at an
angle of 55° to the usual direction
Arrangement of several terminal block
rows one behind the other multi-level
effect with the same design
MKKDS 1/ .
Double-level type with high packing and
connection density
Offset levels for optimum access to the
terminal points
Connection cross section of up to
1.5 mm
2
Technical data
MKDS 1 SMKDS 1 MKKDS 1
Technical data according to IEC/DIN VDE
Rated current / conductor cross section [A] / [mm²] 10
1
) / 1 10
1
) / 1 8
1
) / 1
Rated insulation voltage for pollution degree 2 [V] 200 200 200
Pitch [mm] 3.5 / 3.81 3.5 / 3.81 3.5 / 3.81
Connection capacity
Solid / stranded [mm²] / [mm²] / AWG 0.14 - 1.5 / 0.14 - 1 / 26 - 16 0.14 - 1.5 / 0.14 - 1 / 26 - 16 0.14 - 1.5 / 0.14 - 1 / 26 - 16
Stranded with ferrules without plastic sleeve [mm
2
] 0.25 - 0.5 0.25 - 0.5 0.25 - 0.5
Stranded with ferrules with plastic sleeve [mm
2
] 0.25 - 0.5 0.25 - 0.5 0.25 - 0.5
Multi-conductor connection capacity (two conductors with the same cross section)
Solid / stranded [mm
2
] 0.14 - 0.5 / 0.14 - 0.2 0.14 - 0.5 / 0.14 - 0.2 0.14 - 0.5 / 0.14 - 0.2
Insulation coordination
Surge voltage category / pollution degree III / 3 III / 2 II / 2 III / 3 III / 2 II / 2 III / 3 III / 2 II / 2
Rated insulation voltage [V] 160 200 400 160 200 400 160 200 400
Rated surge voltage [kV] 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Approval data (UL/CUL) Use Group B C D B C D B C D
Nominal voltage [V] 300 - 300 300 - 300 300 - 300
Nominal current [A] 10 - 10 10 - 10 10 - 10
Connection capacity AWG AWG 30 - 16 - 30 - 16 30 - 16 - 30 - 16 30 - 16 - 30 - 16
Approval data (CSA) Use Group B C D B C D B C D
Nominal voltage [V] 150 - 300 150 - 300 150 - 300
Nominal current [A] 10 - 10 10 - 10 10 - 10
Connection capacity AWG AWG 28 - 16 - 28 - 16 28 - 16 - 28 - 16 28 - 16 - 28 - 16
General data
Stripping length [mm] 5 5 5
Screw thread M2 M2 M2
Tightening torque [Nm] 0.22 - 0.25 0.22 - 0.25 0.22 - 0.25
Type of insulation material / insulation material group PA / I PA / I PA / I
Inflammability class according to UL 94 V0 V0 V0
Drill hole diameter / pin dimensions [mm] 1.1 / 0.5 x 0.9 mm 1.1 / 0.5 x 0.9 mm 1.1 / 0.5 x 0.9 mm
For all types Type Page
Marker cards
SK 3,5/2,8 or SK
3,81/2,8
841
Screwdriver
SZS 0,4 x 2,5
Order No.
1205037
Accessories
100806040200
8
10
14
6
4
2
0
16
12
18
20
1
2
3
3 = 0,75 mm
2
2 = 1,0 mm
2
1 = 1,5 mm
2
Ambient temperature [°C]
Current strength
[A]
Current carrying capacity curve
Type: MKDS 1/5-3,5
Tested in accordance with DIN EN 60512-5-2:2003-01
Reduction factor = 1
No. of positions = 5
Metric 3.5 mm pitch Detection lug for models
with a 3.81 mm inch pitch
PCB terminal blocks for MCR technology - COMBICON control
PCB terminal blocks with screw connection for wave soldering processes, currents of up to 32 A

Summary of content (2 pages)