Brochure

No. of pos. Dim. a
[mm]
2 5.00
3 10.00
4 15.00
5 20.00
6 25.00
7 30.00
8 35.00
9 40.00
10 45.00
11 50.00
12 55.00
13 60.00
14 65.00
15 70.00
16 75.00
2 5.08
3 10.16
4 15.24
5 20.32
6 25.40
7 30.48
8 35.56
9 40.64
10 45.72
11 50.80
12 55.88
13 60.96
14 66.04
15 71.12
16 76.20
82 PHOENIX CONTACT
Notes:
In order to avoid tolerances between the terminal blocks and PCB,
the terminal row should be interrupted when the number of posi-
tions exceeds 30.
1
) Please observe the current carrying capacity curves. Other cur-
rent carrying capacity curves are available on request.
PCB terminal blocks with compact
housing dimensions and a flat design
Conductor cross sections up to 1.5 mm2
5.0 or 5.08 mm pitch
MKDSN 1,5/ .
Single-row type with horizontal connec-
tion direction
SMKDSN 1,5/...
Conductor and screwdriver axis at an
angle of 55° to the usual direction
Arrangement of several terminal block
rows one behind the other multi-level
effect with the same design
Connection cross section of up to
1.5 mm
2
Technical data
MKDSN 1,5 SMKDSN 1,5
Technical data according to IEC/DIN VDE
Rated current / conductor cross section [A] / [mm²] 13.5
1
) / 1.5 13.5
1
) / 1.5
Rated insulation voltage for pollution degree 2 [V] 400 400
Pitch [mm] 5 / 5.08 5 / 5.08
Connection capacity
Solid / stranded [mm²] / [mm²] / AWG 0.14 - 1.5 / 0.14 - 1.5 / 26 - 16 0.14 - 1.5 / 0.14 - 1.5 / 26 - 16
Stranded with ferrules without plastic sleeve [mm
2
] 0.25 - 1.5 0.25 - 1.5
Stranded with ferrules with plastic sleeve [mm
2
] 0.25 - 1.5 0.25 - 1.5
Multi-conductor connection capacity (two conductors with the same cross section)
Solid / stranded [mm
2
] 0.14 - 0.75 / 0.14 - 0.75 0.14 - 0.75 / 0.14 - 0.75
Stranded with ferrules without plastic sleeve [mm
2
] 0.25 - 0.5 0.25 - 0.5
Stranded with TWIN ferrule with plastic sleeve [mm
2
] 0.5 - 1 0.5 - 1
Insulation coordination
Surge voltage category / pollution degree III / 3 III / 2 II / 2 III / 3 III / 2 II / 2
Rated insulation voltage [V] 250 400 630 250 400 630
Rated surge voltage [kV] 4 4 4 4 4 4
Approval data (UL/CUL) Use Group B C D B C D
Nominal voltage [V] 300 - 300 300 - 300
Nominal current [A] 10 - 10 10 - 10
Connection capacity AWG AWG 30 - 14 - 30 - 14 30 - 14 - 30 - 14
Approval data (CSA) Use Group B C D B C D
Nominal voltage [V] 150 - 300 150 - 300
Nominal current [A] 10 - 10 10 - 10
Connection capacity AWG AWG 28 - 14 - 28 - 14 28 - 14 - 28 - 14
General data
Stripping length [mm] 6 6
Screw thread M3 M3
Tightening torque [Nm] 0.5 - 0.6 0.5 - 0.6
Type of insulation material / insulation material group PA / I PA / I
Inflammability class according to UL 94 V0 V0
Drill hole diameter / pin dimensions [mm] 1.3 / 0.5 x 1 mm 1.3 / 0.5 x 1 mm
For all types Type Page
Marker cards
SK 5/3,8 or SK 5,08/3,8
842
Screwdriver
SZS 0,6 x 3,5
Order No.
1205053
Insertion bridge
EBP...- 5
853
Accessories
100806040200
25
20
15
10
5
0
1,5 mm
2
Ambient temperature [°C]
Current
c
arrying
capa
city [A]
Current carrying capacity curve
Type: MKDSN 1,5/5
Tested in accordance with DIN EN 60512-5-2:2003-01
Reduction factor = 1
No. of positions: 5
Metric 5 mm pitch Detection lug for
models with a 5.08 mm inch pitch
PCB terminal blocks for MCR technology - COMBICON control
PCB terminal blocks with screw connection for wave soldering processes, currents of up to 32 A

Summary of content (2 pages)