Datasheet

PSC 1,5/ 5-F Order No.: 1841912
http://eshop.phoenixcontact.se/phoenix/treeViewClick.do?UID=1841912
Phoenix Contact AB Page 2 / 5
http://www.phoenixcontact.se May 17, 2011
Technical data
Range of articles PSC 1,5/..-F
Insulating material group I
Connection in acc. with standard EN-VDE
Nominal current I
N
8 A
Nominal voltage U
N
250 V (for applications in metal or metal-plated housings, the
degree of protection "safety extra-low voltage" must be used.)
Nominal cross section 1.5 mm²
Maximum load current 8 A
Insulating material PA
Inflammability class acc. to UL 94 V0
Nominal voltage, UL/CUL Use Group B 300 V
Nominal current, UL/CUL Use Group B 8 A
Nominal voltage, UL/CUL Use Group D 300 V
Nominal current, UL/CUL Use Group D 8 A
Connection data
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section stranded min. 0.14 mm²
Conductor cross section stranded max. 1.5 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve min.
0.25 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve max.
1.5 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve min.
0.25 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve max.
1.5 mm²
Conductor cross section AWG/kcmil min. 28
Conductor cross section AWG/kcmil max 16
Minimum AWG according to UL/CUL 30
Maximum AWG according to UL/CUL 14
Certificates