Datasheet

https://www.phoenixcontact.com/us/produkte/2281225
Nov 14, 20131/7
Interface module-FLKM-D50 SUB/B-2281225
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in
the user's documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
The illustration shows version
FLKM-D37 SUB/S
VARIOFACE module, with screw connection and D-Subminiature socket strip, for mounting on NS
35/7.5 or NS 32, 50-pos.
Key commercial data
package_quantity
5
GTIN
4017918054656
Technical data
Dimensions
Width
112.5 mm
Height
77 mm
Depth
58.5 mm
Ambient conditions
Ambient temperature (operation)
-20 °C ... 50 °C
Ambient temperature (storage/transport)
-20 °C ... 70 °C
General
Nominal voltage U
N
125 V AC/DC
Max. current carrying capacity per branch
2.5 A
Max. current carrying capacity per branch
1.5 A (with even load on all branches)
Number of positions
50
Test voltage
800 V (50 Hz, 1 min.)
Mounting position
Any
Standards/regulations
IEC 60664
Standards/regulations
IEC 60664 A
Standards/regulations
DIN VDE 0110
Standards/regulations
DIN VDE 0160 (in parts)
Pollution degree
2
Surge voltage category
II
Rated surge voltage
1.2 kV