Datasheet

https://www.phoenixcontact.com/us/produkte/2313669
Nov 13, 20132/12
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Technical data
Ambient conditions
Noise immunity
EN 61000-6-2
Serial interface
Interface 1
V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN
66259-1
Interface
V.24 (RS-232)
Connection method
D-SUB-9 male connector
Transmission length
max. 15 m
Termination resistor
390 Ω - 180 Ω - 390 Ω (can be connected)
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
13
Data flow control/protocols
Software handshake, Xon/Xoff, hardware handshake (RTS/CTS),
3964R-compatible, Modbus (RTU/ASCII), transparent protocol -
additional protocols supported
Serial transmission speed
0.11/0.3/1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4 kbps, NRZ
Interface 2
SHDSL interface according to ITU-T G.991.2.bis
Connection method
2 x 2-pos. COMBICON plug-in screw terminal blocks
Transmission length
up to 20 km (Depending on data rate and cable cross section)
Serial transmission speed
4-wire operation: 64 kbps ... 30 Mbps
Serial transmission speed
2-wire operation: 32 kbps ... 15.3 Mbps
Interface 3
USB 2.0
Connection method
Mini-USB type B, 5-pos.
Transmission length
max. 5 m (Only for configuration and diagnostics)
Interface 4
RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN
66348-1
Interface
RS-422
Connection method
Plug-in/screw connection via COMBICON
File format/coding
Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1
parity bit (even, odd, mark, space, none), 9/10/11-bit character
length
Transmission length
≤ 1200 m
Termination resistor
390 Ω - 180 Ω - 390 Ω (can be connected)
Data flow control/protocols
Automatic control // Modbus RTU/ASCII
Serial transmission speed
1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000
kbps, NRZ
Interface 5
RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485
2-wire
Interface
RS-485
Connection method
Plug-in/screw connection via COMBICON
File format/coding
Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity,
10/11-bit character length