Instructions

Table Of Contents
PSI-MODEMSHDSL/SERIAL
1-4
PHOENIX CONTACT 104275_en_c00
Housing dimensions
Figure 1-1 Housing dimensions (in mm)
Electrical isolation DIN EN 50178
(Supply // RS-485, RS-422 // DSL port A // DSL port B // FE)
MTBF according to Telcordia standard 1004 years
Telcordia standard, 25°C ambient temperature, 21% operating cycles
(5 days a week, 8 hours a day)
199 years
Telcordia standard, 40°C ambient temperature, 34.25% operating cycles
(5 days a week, 8 hours a day)
Test voltage 1.5 kV AC, 50 Hz, 1 min.
Vibration resistance According to IEC 60068-2-6: 5g, 150 Hz
Shock resistance 15g in each space direction, according to IEC 60068-2-27
Noise emission EN 55011
Noise immunity EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
UL, USA/Canada UL 508 listed in preparation
Manufacturer's declaration EN 50121-4 (Railway applications - Electromagnetic compatibility, Part 4:
Emission and immunity of the signaling and telecommunications apparatus)
Exceptions include installations within the 3 m area and safety-related de-
vices. For these devices, there are further requirements according to
EN 50121-4 Table 1, Note 1.
Section 1, Paragraph 3 of EN 50121-4 applies. Phoenix Contact QUINT power
supply units are to be used directly on the device.
Conformity assessment according to directive 94/9/EC X II 3 G Ex nAC IIC T4 X
General data (Fortsetzung)
104275A001
114,5
35
99
PSI-MODEM-SHDSL/SERIAL
Ord.-No. 23 13 669
VCC
DG
RD
TD
ERR
LINK
STAT
LINK
STAT
DSL A
DSL B
SERIAL
RS232
USB
TERM
RS232