Instructions

Table Of Contents
PSI-MODEMSHDSL/SERIAL
5-6
PHOENIX CONTACT 104275_en_c00
095 RS-232 interface no lon-
ger connected
The RS-232 line was removed
The connected RS-232 de-
vice was removed
Power failure of the connected
RS-232 device
Only interesting if the termination
of the connection was not intended
and the time of the disconnection
is to be determined.
096 Sporadic parity errors Sporadically, parity errors occur
on the serial interface.
Check the wiring of the serial inter-
face. If the serial data line is rela-
tively long compared to the used
data rate, or the quality of the line is
not good, reduce the serial data
rate.
096 Sporadic stop bit errors Data packets contain sporadic
stop bits errors.
Check the wiring of the serial inter-
face. If the serial data line is rela-
tively long compared to the used
data rate, or the quality of the line is
not good, reduce the serial data
rate.
097 Sporadic protocol viola-
tions
Sporadically there are long peri-
ods of "zeros" on the serial inter-
face.
Possible cause:
the serial data rate may be
configured wrong
there may be a short circuit on
the serial data line
a driver of a device connected
to the serial port may be de-
fective.
Check the device configurati-
on (serial data rate correct?)
Check the installation of the
serial interface.
If the serial data line is relative-
ly long compared to the used
data rate, or the line quality is
not good, if applicable reduce
the serial data rate
098 Sporadic noise Possible cause:
the serial data rate may be
configured wrong
there may be a short circuit on
the serial data line
a driver of a device connected
to the serial port may be de-
fective.
Check the device configurati-
on (serial data rate correct?)
Check the installation of the
serial interface.
If the serial data line is relative-
ly long compared to the used
data rate, or the line quality is
not good, if applicable reduce
the serial data rate
100 There is no more data re-
ceived from the remote
device(s).
For one minute there was no data
received from the SHDSL connec-
tion.
Although data was received previ-
ously.
Determining the moment of a com-
munication interruption from the
remote device(s).
Table 5-1 Diagnostic IDs
No. Meaning LED Possible cause(s) Remedy