PSI-MODEMSHDSL/SERIAL
5-8
PHOENIX CONTACT 104275_en_c00
186 Device supplied via USB
port only
VCC LED blink-
ing (1 Hz)
This message is generated when
the device is supplied via the USB
port only. No data traffic may take
place, since the DSL chip is reset
to save energy.
187 DIAG LED set DIAG LED on An error event caused the DIAG
LED to be set.
188 DIAG LED reset DIAG LED off The DIAG LED was reset (auto-
matically or manually).
189 reserved
190 No frequent link losses
anymore
After link losses occurred fre-
quently, the link is stable now (for
10 minutes at least), or the link has
been interrupted for 10 minutes at
least without having found a link
partner.
191 reserved
192 reserved
193 reserved
194 reserved
195 reserved
196 reserved
197 reserved
198 A DTE device is con-
nected to the RS-232 in-
terface.
There is a device connected via a
1:1 cable which acts as DTE (cor-
responds to eg a PC).
There is a device connected via a
crossover cable which acts as
DCE (corresponding to eg a con-
ventional modem).
199 A DCE device is con-
nected to the RS-232 in-
terface.
There is a device connected
via a 1:1 cable which acts as
DCE (corresponding to eg a
conventional modem).
There is a device connected
via a crossover cable which
acts as DTE (corresponds to
eg a PC).
200 No more too long frames
are received.
Previously, frames were received
which were too long (longer than
500 characters). Since one minute
no more too long frames were re-
ceived.
Table 5-1 Diagnostic IDs
No. Meaning LED Possible cause(s) Remedy