Datasheet

1Description
IEC 62061
SILCL
Safety relay for emergency stop and safety door
monitoring
PSR-MC20
© PHOENIX CONTACT
Data sheet
Intended Use
The PSR-MC20 safety relay can be used to monitor single-
channel signal generators, e.g.,emergency stop buttons
and safety door locking mechanisms, and to control actua-
tors.
The safety relay is equipped with three enabling current
paths that drop out without delay corresponding to stop cat-
egory0 according to EN60204-1.
The enabling current paths are controlled as an automatic or
manual, monitored start once the sensor circuit has been
closed.
With the manual, monitored reset device, a machine start
may not be triggered in accordance with ENISO13849-1.
Features
Safety relay for emergency stop and safety door moni-
toring
Suitable up to category1, PLc (ENISO13849-1),
SILCL1(EN62061)
Depending on the application, suitable up to catego-
ry4, PLe (ENISO13849-1), SILCL3(EN62061)
1 single-channel sensor circuit
3 undelayed enabling current paths
1 digital signal output
Option of screw or spring-cage terminal blocks for plug-
in
12.5mm housing width
WARNING: Risk of electric shock
Observe the safety instructions in the corresponding section!
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
This data sheet meets the same requirements as the original operating instructions in terms of contents and is
valid for all products listed on the following pages.
106172_en_01
2015-03-11

Summary of content (16 pages)