Datasheet

PSR-MC34
106174_en_01 PHOENIX CONTACT 16
15.8 Single-channel safety door monitoring/manual,
monitored start
Single-channel safety door monitoring
–Manual, monitored start
No cross-circuit detection in the sensor circuit
Suitable up to category1, PLc (ENISO13849-1),
SILCL1(EN62061)
Figure 19 Single-channel safety door monitoring/man-
ual, monitored start
15.9 Magnetic switch monitoring/automatic start
Two-channel magnetic switch monitoring
Automatic start
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061), if cross-circuits in the control to
the actuator can be ruled out
Figure 20 Magnetic switch monitoring/automatic start
15.10 Magnetic switch monitoring/manual, monitored
start
Two-channel magnetic switch monitoring
Manual, monitored start
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061), if cross-circuits in the control to
the actuator can be ruled out
Figure 21 Magnetic switch monitoring/manual, moni-
tored start