Datasheet

1Description
IEC 62061
SILCL
Safety relays for monitoring non-equivalent signal
generators
PSR-MC50
© PHOENIX CONTACT
Data sheet
Intended Use
The PSR-MC50 safety relay can be used to monitor two-
channel non-equivalent signal generators, e.g.,magnetic
switches, as well as to control actuators.
The safety relay is equipped with three enabling current
paths that drop out without delay corresponding to stop cat-
egory0 according to EN60204-1.
The enabling current paths are controlled as an automatic or
manual, monitored start once sensor circuit channel1 has
been closed and channel2 has been opened.
With the manual, monitored reset device, a machine start
may not be triggered in accordance with ENISO13849-1.
Features
Safety relays for monitoring non-equivalent signal gen-
erators, e.g.,magnetic switches
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061)
1 two-channel non-equivalent sensor circuit
3 undelayed enabling current paths
1 digital signal output
Option of screw or spring-cage terminal blocks for plug-
in
12.5mm housing width
WARNING: Risk of electric shock
Observe the safety instructions in the corresponding section!
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
This data sheet meets the same requirements as the original operating instructions in terms of contents and is
valid for all products listed on the following pages.
106176_en_01
2015-03-11