15 Application examples
Key:
Applications with the PSR-MC50
15.1 Magnetic switch monitoring/automatic start
– Two-channel, non-equivalent magnetic switch monitor-
ing
– Automatic start
– Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061), if cross-circuits in the control to
the actuator can be ruled out
Figure 12 Magnetic switch monitoring/automatic start
15.2 Magnetic switch monitoring/manual, monitored
start
– Two-channel, non-equivalent magnetic switch monitor-
ing
– Manual, monitored start
– Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061), if cross-circuits in the control to
the actuator can be ruled out
Figure 13 Magnetic switch monitoring/manual, moni-
tored start
S1 = Mechanical safety door switch
S2 = Manual reset device
S3 = Solenoid switch
K1/K2 = Contactors
Cross-circuits in the cable installation can be
excluded if the safety relay and external con-
tactors K1 and K2 are located in the same
electrical installation space.