Datasheet

PSR-MC50
106176_en_01 PHOENIX CONTACT 15
15.3 Safety door monitoring/automatic start
Non-equivalent safety door monitoring
Automatic start
Suitable up to category1, PLc (ENISO13849-1),
SILCL1(EN62061)
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061), if cross-circuits in the control can
be excluded from the actuator and when using the two
switches in design1
Figure 14 Safety door monitoring/automatic start
15.4 Safety door monitoring/manual, monitored
start
Non-equivalent safety door monitoring
Manual, monitored start
Suitable up to category1, PLc (ENISO13849-1),
SILCL1(EN62061)
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061), if cross-circuits in the control can
be excluded from the actuator and when using the two
switches in design1
Figure 15 Safety door monitoring/manual, monitored
start
K1
K2
M
24V
K1
K2
N
L
S1
0V
K2
K1
A1
A2
13
14
PSR-MC50
S12
S13
( )
M1
( )
23
24
( )
34
33
S34
( )
K1
K2
M
24V
K1
K2
N
L
0V
S1
K1
K2
S2
A1
A2
13
14
PSR-MC50
S12
S34
S13
( )
( )
M1
( )
23
24
( )
34
33