Datasheet

PSR-PC20
106255_en_00 PHOENIX CONTACT 4
Maximum switching voltage 250 V AC/DC (N/O contact)
26.4 V DC (N/C contact)
Nominal current 6 A (N/O contact)
Limiting continuous current 6 A (13/14, see to derating)
4 A (13F/14, see to derating)
100 mA (N/C contact)
Maximum inrush current 6 A (N/O contact)
100 mA (N/C contact)
Inrush current, minimum 3 mA (N/O contact)
1 mA (N/C contact)
Sq. Total current 36 A
2
(see to derating)
Switching capacity min. 60 mW
Mechanical service life 10 x 10
6
cycles
Output fuse 6 A gL/gG (N/O contact 13/14)
4 A gL/gG (for low-demand applications)
150 mA fast blow (Confirmation current path)
Output data
Alarm outputs
Number of outputs 1 (digital, PNP)
Voltage 22 V DC (U
D
-2V)
Current max. 100 mA
Maximum inrush current 500 mA (t=1ms at U
s
)
Short-circuit protection no
General data
Relay type Electromechanically forcibly guided, dust-proof relay.
Nominal operating mode 100% operating factor
Degree of protection IP20
Min. degree of protection of inst. location IP54
Mounting type DIN rail mounting
Mounting position vertical, horizontal, with front of module upward
Assembly instructions See derating curve
Type of housing PBT yellow
Clearances and creepage distances between the power circuits DINEN50178, EN60079-15
Rated insulation voltage 250 V AC
Rated surge voltage/insulation Safe isolation, 6kV reinforced insulation from control circuit, start circuit, confir-
mation current path, signal output to the enabling current path; 4 kV/basic insula-
tion between all current paths and housing
Pollution degree 2
Surge voltage category III
Dimensions Screw connection Spring-cage connection
W x H x D 12.5 x 112.2 x 114.5 mm 12.5 x 116.6 x 114.5 mm
Connection data Screw connection Spring-cage connection
Conductor cross section, solid 0.2 mm² ... 2.5 mm² 0.2 mm² ... 1.5 mm²
Conductor cross section, stranded 0.2 mm² ... 2.5 mm² 0.2 mm² ... 1.5 mm²
Conductor cross section AWG/kcmil 24 ... 12 24 ... 16
Stripping length 7 mm 8 mm
Screw thread M3