Datasheet

https://www.phoenixcontact.com/us/produkte/2864529
Nov 14, 20131/6
Head-mounted transducer-MCR-FL-HT-T-I-2864529
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in
the user's documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
MCR head-mounted temperature transducers: Programmable loop-powered temperature transducers
for resistance thermometers, thermocouples, resistance-type sensors and voltage sensors
Product Features
Freely programmable via MCR/PI-CONF-WIN
For installation in connecting head, form B
Two-wire transmitter for resistance thermometers, thermocouples, resistance-type sensors, and voltage sensors
Key commercial data
package_quantity
1
GTIN
4017918893224
Technical data
Ambient conditions
Ambient temperature (operation)
-40 °C ... 85 °C
Degree of protection
IP00, IP66 (integrated in the connecting head)
Input data
Configurable/programmable
Yes, programmable
Sensor types (RTD) that can be used
Pt, Ni (100, 500, 1000); minimum measurement range 10 K
Sensor types that can be used (TC)
B, C, D, E, J, K, L, N, R, S, T, U; minimum measurement range 50
K/500 K
Linear resistance measuring range
(Resistance-type sensor from 10 Ω to 400 Ω and from 10 Ω to
2000 Ω; minimum measurement range 10 Ω/100 Ω)
Connection method
2, 3, 4-wire
Output data
Output name
Current output
Current output signal
4 mA ... 20 mA
Current output signal
20 mA ... 4 mA
Output current with wire break
≤ 3.6 mA or ≥ 21 mA (adjustable)
Output current with short-circuit
≤ 3.6 mA or ≥ 21 mA (adjustable, not for thermocouples)
Output current range with overrange/underrange
≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease)
Load/output load current output
(Max (V
supply
- 8 V) / 0.025 A (current output))
Power supply
Name
Loop-powered

Summary of content (6 pages)