Datasheet

TRIO-PS/3AC/24DC/5
103346_en_00 PHOENIX CONTACT 5
Conformance with EMC directive 2004/108/EC
Noise immunity according to EN 61000-6-2
Electrostatic discharge EN 61000-4-2
Housing Level 3
Contact discharge 8 kV
Discharge in air 8 kV
Comments Criterion B
Electromagnetic HF field EN 61000-4-3
Housing Level 3
Frequency range 80 MHz ... 3 GHz
Field intensity 10 V/m
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 4 kV (level 4 - asymmetrical: conductor to ground)
Output 2 kV (level 3 - asymmetrical: conductor to ground)
Comments Criterion B
Surge current loads (surge) EN 61000-4-5
Input 4 kV (level 4 - asymmetrical: conductor to ground)
2 kV (level 4 - symmetrical: conductor to conductor)
Output 1 kV (Level 3 - symmetrical: Conductor to conductor)
2 kV (level 3 - asymmetrical: conductor to ground)
Comments Criterion B
Conducted interference EN 61000-4-6
Input/output Level 3 - asymmetrical
Frequency range 150 kHz ... 80 MHz
Voltage 10 V
Comments Criterion A
Voltage dips EN 61000-4-11
Input (mains buffering > 10 ms)
Comments Criterion B
Emitted interference in acc. with EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential